Page 172 of 492
Chapter 5 — ISDN BRI line and packet data implementation
553-3011-311
Standard 7.0
May 1999
Table 11
U DSL cable calculations
Item
Gauge
AWG
Insulation type
Loss
dB/km
(dB/kft)
Length
km (kft)
Loss
dB
1
19
PIC
3.3 (1.0)
2
19
PULP
3.6 (1.1)
3
22
PIC
4.6 (1.4)
4
22
PIC
4.9 (1.5)
5
24
PIC
5.9 (1.8)
6
24
PULP
6.3 (1.9)
7
26
PIC or PULP
9.2 (2.8)
8
Customer premises wiring
5.9 (1.8)
9
Local exchange wiring
9.2 (2.8)
10
Bridge tap 1
11
Bridge tap 2
12
Bridge tap 3
13
Bridge tap 4
14
Bridge tap 5
15
Bridge tap 6
Total loss in dB (add items 1 through 15)
Recommended maximum loss = 40 dB