Chapter 5 — ISDN BRI line and packet data implementation
Page 203 of 492
Option 11C
ISDN BRI Administration and Maintenance
Connecting ISDN BRI terminals
To complete the installation of ISDN BRI equipment, the ISDN BRI
terminals must be connected to the Option 11. This consists of:
— Connecting the Option 11 to the cross-connect terminal
— Cross-connecting the wiring
— Connecting the terminating resistor (A0378866) to the SILC DSL
— Connecting ISDN BRI terminals to the DSL
— Initializing the terminals
Modular cord is used to connect a terminal to a DSL. The maximum length
of this connection is 10 m (3.5 ft) from the terminal to the RJ-45 jack.
Figure 28 shows a typical DSL and ISDN BRI terminals connected to the
Option 11.
Summary of Contents for Meridian 1 Option 11C
Page 2: ......
Page 4: ...553 3011 311 Standard 7 0 May 1999...
Page 12: ...viii Contents 553 3011 311 Standard 7 0 May 1999...
Page 14: ...Page x About this guide 553 3011 311 Standard 7 0 May 1999...
Page 166: ...Page 152 of 492 Chapter 4 Network clocking 553 3011 311 Standard 7 0 May 1999...
Page 318: ...Page 304 of 492 Chapter 6 ISDN BRI trunk implementation 553 3011 311 Standard 7 0 May 1999...
Page 434: ...Page 420 of 492 Chapter 8 Service changes and maintenance 553 3011 311 Standard 7 0 May 1999...
Page 446: ...Page 432 of 492 Chapter 9 ISDN BRI traffic reports 553 3011 311 Standard 7 0 May 1999...
Page 492: ...Page 478 of 492 Appendix A 2Mb PRI implementation 553 3011 311 Standard 7 0 May 1999...