CAUTION
Risk of connector pin damage
To prevent damage to the connector pins, ensure that
the cable connector aligns correctly with the hard drive
connector before pushing it into place.
c. Route the cable above the CPU through the vacant space at the top of the server.
d. Connect the other end of the cable as follows:
— Connect hard drive 1 to the SCSI controller using the same SCSI cable that routes to
the tape drive. The terminator should end the SCSI cable after the tape drive connection.
e. For proper cooling and airflow, neatly fold and secure the excess signal cable above the
CPU. Use a tie wrap or cable clip to secure the cable.
.
CAUTION
Risk of equipment damage
Ensure that any cables in the proximity of the fans are
kept away from the fans. If a cable is caught in a fan,
the fan will break.
4. Connect the hard drive’s power cable.
Note
: The connector is keyed so that you cannot connect it upside down.
5. At the front of the server, slide the drive into the bay until it clicks into place.
6. Secure the drive carrier to the front of the server with the screws you removed earlier.
Tighten the screws firmly.
7. Ensure that all media drive cable connections are secure.
Note
: Connectors could be dislodged when you slide the hard drive all the way inside the bay.
.
CAUTION
Risk of data loss, corruption, or system malfunction
If the hard drive cable connections are loose, data loss,
data corruption, or system malfunction can occur.
8. Reinstall the fans (if removed) and upper fan holder foam.
•
For instructions on reinstalling the fans, see “To install a front system fan” on page 104.
•
For instructions on replacing the upper fan holder foam, see “To replace the upper fan
holder foam” on page 101.
9. Reinstall the server’s side cover.
10. Reconnect the peripheral device and power cables.
11. Power up the server.
12. Result: Hard drive replacement is complete.
Installing/Replacing a Tape Drive
Introduction
If tape drive is part of your purchase from Nortel, the tape drive is preinstalled at the factory.
However, if it becomes faulty or if a new drive is purchased, follow the procedures in this section to
replace and/or install it.
Nortel Hospitality Messaging Server 400
-117-
Maintenance Guide
Summary of Contents for HMS400
Page 2: ......
Page 4: ...April 2006 Nortel Hospitality Messaging Server 400 4 Maintenance Guide ...
Page 8: ...April 2006 PMSI Log Files 154 Nortel Hospitality Messaging Server 400 8 Maintenance Guide ...
Page 10: ...April 2006 Nortel Hospitality Messaging Server 400 10 Maintenance Guide ...
Page 14: ...April 2006 Nortel Hospitality Messaging Server 400 14 Maintenance Guide ...
Page 16: ...April 2006 Nortel Hospitality Messaging Server 400 16 Maintenance Guide ...
Page 28: ...April 2006 Nortel Hospitality Messaging Server 400 28 Maintenance Guide ...
Page 30: ...April 2006 Nortel Hospitality Messaging Server 400 30 Maintenance Guide ...
Page 42: ...April 2006 Nortel Hospitality Messaging Server 400 42 Maintenance Guide ...
Page 58: ...April 2006 Nortel Hospitality Messaging Server 400 58 Maintenance Guide ...
Page 60: ...April 2006 Nortel Hospitality Messaging Server 400 60 Maintenance Guide ...
Page 70: ...April 2006 Nortel Hospitality Messaging Server 400 70 Maintenance Guide ...
Page 72: ...April 2006 Nortel Hospitality Messaging Server 400 72 Maintenance Guide ...
Page 82: ...April 2006 Nortel Hospitality Messaging Server 400 82 Maintenance Guide ...
Page 84: ...April 2006 Nortel Hospitality Messaging Server 400 84 Maintenance Guide ...
Page 96: ...April 2006 Nortel Hospitality Messaging Server 400 96 Maintenance Guide ...
Page 112: ...April 2006 Nortel Hospitality Messaging Server 400 112 Maintenance Guide ...
Page 126: ...April 2006 Nortel Hospitality Messaging Server 400 126 Maintenance Guide ...
Page 128: ...April 2006 Nortel Hospitality Messaging Server 400 128 Maintenance Guide ...
Page 138: ...April 2006 Nortel Hospitality Messaging Server 400 138 Maintenance Guide ...
Page 140: ...April 2006 Nortel Hospitality Messaging Server 400 140 Maintenance Guide ...
Page 148: ...April 2006 Nortel Hospitality Messaging Server 400 148 Maintenance Guide ...
Page 157: ......