Managing ANH Repeater Ports
308614-14.20 Rev 00
5-5
Testing and Resetting ANH Repeater Ports
You can use Site Manager to test and reset ANH repeater ports.
Site Manager Procedure
You do this
System responds
1. In the Site Manager main window, choose
Tools
.
The Tools menu opens.
2. Choose
Configuration Manager
.
The Configuration Manager menu opens.
3. Choose
Dynamic
.
The Configuration Manager window
opens, displaying the real-time router
hardware and software configuration.
4. Choose
Platform
.
The Platform menu opens.
5. Choose
Setup Repeater
.
The Setup Repeater menu opens.
6. Choose
Group Parameters
.
The Group Parameters window opens.
7. Set the following parameters:
•
Reset
•
Selftest
Click on
Help
or refer to the parameter
descriptions beginning on page A-9.
The Configuration Manager tests each
repeater port and indicates in a log file
whether the ports pass the diagnostics.
8. Click on
OK
.
Site Manager executes the action(s)
specified in the Group Parameters
window and then closes the window.
Note:
The repeater port self-test does not disrupt traffic flow. Resetting a
repeater port does disrupt traffic flow; however, it does not affect the
management counters defined in the RFC 1516 MIB specification.