2.6.2.23 Operator Lockout Set Command (continued)
EXAMPLE:
If the supervisor password is 0000 and if Dispense Time, Dispense Pressure, and Dispense Vacuum
need to be locked out, the text packet is:
(STX) + 39 + EG-- + PA0000DT1DP1DV1M0DC0DM0AI0AR0AL0MM0PU0VU0LA0CL0 79 + (ETX)
Length of this text packet:
Decimal 57 or hexadecimal 39
The above text packet in hexadecimal format:
STX
3
9
E
G
space space
P
A
0
0
0
0
0x02
0x33
0x39
0x45
0x47
0x20
0x20
0x50
0x41
0x30
0x30
0x30
0x30
D
T
1
D
P
1
D
V
1
M
0
D
C
0x44
0x54
0x31
0x44
0x50
0x31
0x44
0x56
0x31
0x4D
0x30
0x44
0x43
0
D
M
0
A
I
0
A
R
0
A
L
0
0x30
0x44
0x4D
0x30
0x41
0x49
0x30
0x41
0x52
0x30
0x41
0x4C
0x30
M
M
0
P
U
0
V
U
0
L
A
0
C
0x4D
0x4D
0x30
0x50
0x55
0x30
0x56
0x55
0x30
0x4C
0x41
0x30
0x43
L
0
C
O
0
A
M
0
7
9
ETX
0x4C
0x30
0x43
0x4F
0x30
0x41
0x4D
0x30
0x37
0x39
0x03
2.6.2.24 Set Language Command
This command sets the language for the dispenser.
Client command and data:
ED--LI: Language Index
0 =
English
1 =
French
2 =
German
3 =
Spanish
4 =
Italian
5 =
Chinese
6 =
Japanese
7 =
Korean
EXAMPLE:
To set the language as Spanish, the text packet is: (STX) + 05 + ED-- + 3 + 9F + (ETX)
The above text packet in hexadecimal format:
STX
0
5
E
D
space space
3
9
F
ETX
0x02
0x30
0x35
0x45
0x44
0x20
0x20
0x33
0x39
0x46
0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
61
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.