2.6.2.20 Set Trigger Value Command
This command downloads the 5-digit trigger value into the current memory location.
Client command and data:
EQ--Tttttt
ttttt:
Trigger Value. 00001–99999
EXAMPLE:
If the trigger value is 1000, the text packet it: (STX) + 0A + EQ-- + 74 + (ETX)
Length of this text packet:
Decimal 10 or hexadecimal 0A
The above text packet in hexadecimal format:
STX
0
A
E
Q
space space
T
0
1
0
0
0
7
0x02
0x30
0x41
0x45
0x51
0x20
0x20
0x54
0x30
0x31
0x30
0x30
0x30
0x37
4
ETX
0x34
0x03
2.6.2.21 Set the Real Time Clock Command
This command sets the time for the real time clock on the dispenser.
Client command and data:
EB--HhhMmmAMa
hh:
Hours. 0–23 for 24 hour format, 1–12 for 12 hour format
mm:
Minutes. 0–59
a:
Hour format. 0 = AM, 1 = PM, 2 = 24 hour format
EXAMPLE:
To set the time as 14:05 and the hour format to 24-Hour, the text packet is:
(STX) + 0D + EB-- + H14 A6 + (ETX)
Length of this text packet:
Decimal 13 or hexadecimal 0D
The above text packet in hexadecimal format:
STX
0
D
E
B
space space
H
1
4
M
0
5
A
0x02
0x30
0x44
0x45
0x42
0x20
0x20
0x48
0x31
0x34
0x4D
0x30
0x35
0x41
M
2
A
6
ETX
0x4D
0x32
0x41
0x36
0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
59
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.