• The Pressure Alarm can activate the Alarm Output Signal on the
digital I/O connector. A check mark in the box next to Enable
Pressure Alarm Output Signal indicates that the Alarm Output
signal is enabled for Pressure Alarm signals.
• The Pressure Alarm Signal can be latched. When a Pressure
Alarm occurs and it is latched, the user must reset the Alarm
before dispense cycles can be resumed. To reset the Pressure
Alarm, view the main screen and use the Up / Down (8 / 2) keys
and the Left / Right (4 / 6) keys to select the Pressure Alarm.
Pressing the F2 (Reset) function key will reset the Pressure
Alarm. A check mark in the box next to Enable Pressure Alarm
Latching indicates the Pressure Alarm Latch is enabled.
• The Auto Increment Alarm will activate when Auto Increment is
active, the memory address is set at the End Address and the
dispense count / timer has passed the Trigger value. The Auto
Increment Alarm is enabled when a check mark is shown in the
box next to Enable Auto Increment Alarm.
• The Auto Increment Alarm can activate the Alarm Output Signal
on the digital I/O connector. A check mark in the box next to
Enable Auto Inc Alarm Output Signal indicates that the Alarm
Output Signal is enabled for Auto Increment Alarms.
• The Auto Increment Alarm is always latched. To reset the
Auto Increment Alarm, view the main screen and use the Up /
Down (8 / 2) keys and the Left / Right (4 / 6) keys to select the
Auto Increment Alarm. The F2 function key will now be labeled
“RESET”. Pressing the F2 function key will reset the Auto
Increment Alarm.
Alarm Options Screen (continued)