2.6.3.7 Total Status Read Command
This command returns the status and values of the Auto Increment Mode and the dispense mode (Timed, Steady, or
Teach).
NOTE:
This is the same command as the Musashi 808FX Total Status command, so the Vacuum Interval Mode
status is included in the text packet. However, the Ultimus V dispenser does not support this mode, so this data
defaults to safe values.
Client command and data:
(STX) + 04 + AU-- + C6 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
A
U
space space
C
6
ETX
0x02
0x30
0x34
0x41
0x55
0x20
0x20
0x43
0x36
0x03
NOTE:
“D0” is the letter “D” followed by the digit “0.”
Return Format:
D0AIiMmSssssDdddddddVIqVvvvvIttttTMxSAaaaEAeee
i:
Auto Increment mode status. 0 = Off, 1 = Enabled
m:
Auto Increment mode function. 1 = Timer, 2 = Count, 4=Auto Sequence Mode
ssss:
Trigger Value. The upper digit is truncated to make this function compatible with the Musashi command
ddddddd:
Current Timer / Counter value
q:
Defaulted to 0
vvvv:
Defaulted to 0001
tttt:
Defaulted to 0001
x:
Dispense mode. 0 = Timed, 1 = Steady, 2 = Teach
aaa:
Auto Increment Start Address. 000–399
eee:
Auto Increment End Address. 000–399
EXAMPLE:
If Auto Increment mode is On, the Auto Increment Mode function is Count, the Trigger value is 100, the
current Timer / Counter value is 10500, the dispense mode is Timed, the Auto Increment Start Address is 001, and
the Auto increment End Address is 050, the text packet received from the dispenser is:
(STX) + 2E + D0AI1M2S0100D0010500VI0V0001I0001TM0SA00 2C + (ETX)
Length of the response text packet:
Decimal 46 or hexadecimal 0x2E
The above text packet in hexadecimal format:
STX
2
E
D
0
A
I
1
M
2
S
0
1
0
0x02
0x32
0x45
0x44
0x30
0x41
0x49
0x31
0x4D
0x32
0x53
0x30
0x31
0x30
0
D
0
0
1
0
5
0
0
V
I
0
V
0
0x30
0x44
0x30
0x30
0x31
0x30
0x35
0x30
0x30
0x56
0x49
0x30
0x56
0x30
0
0
1
I
0
0
0
1
T
M
0
S
A
0
0x30
0x30
0x31
0x49
0x30
0x30
0x30
0x31
0x54
0x4D
0x30
0x53
0x41
0x30
0
1
E
A
0
5
0
2
C
ETX
0x30
0x31
0x45
0x41
0x30
0x35
0x30
0x32
0x43
0x03
Appendix B — RS‑232 Protocol (continued)