Dispense Count Mode
Enabling Auto Increment in Dispense Count mode allows the Ultimus V to increase the memory cell address from
the Start Address to the End address based on the number of dispense cycles that occur.
The Shot variable on the main screen tracks the number of dispense cycles for the current memory address and
resets to zero when the memory cell address advances to the next address.
In Count mode, the Trigger value represents the number of dispense cycles that need to occur before the current
memory cell is advanced to the next location. The valid range is 00001 to 99999 dispense cycles. The total dispense
cycle count for the unit is saved and will continue to increment while in Auto Increment mode.
Time Mode
Enabling Auto Increment in Time Mode will allow the Ultimus V to increment the memory cell address from the Start
Address to the End Address, based on the number of seconds that have elapsed.
When Time mode is selected, the real time clock becomes a counter that counts, in seconds, from 00000 to 99999.
The counter resets to all zeros when the memory cell address increments.
In Time mode, the Trigger value represents the amount of time that needs to elapse before the current memory cell
is advanced to the next location. The valid range is 00001 to 99999 seconds.
Auto Sequence Mode
Enabling Auto Increment in Auto Sequence mode allows the Ultimus V to increase the memory cell address from the
Start Address to the End address based on the number of dispense cycles that occur.
The Shot variable on the main screen tracks the number of dispense cycles for the current memory address and
resets to zero when the memory cell address advances to the next address.
As in Count mode, the Trigger value represents the number of dispense cycles that need to occur before the current
memory cell is advanced to the next location. The valid range is 00001 to 99999 dispense cycles. The total dispense
cycle count for the unit is saved and will continue to increment while in Auto sequence mode.
Once the trigger value is reached for the End address, the Ultimus V will automatically reset the memory cell
address back to the Start address and continue increasing the memory cell address as before. The auto increment
alarm will not be set in this mode.