2.6.3.5 Pressure Units Read Command
This command returns the units the dispenser is using to display pressure.
Client command and data:
(STX) + 04 + E4-- + E3 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
E
4
space space
E
3
ETX
0x02
0x30
0x34
0x45
0x34
0x20
0x20
0x45
0x33
0x03
NOTE:
“D0” is the letter “D” followed by the digit “0.”
Return Format:
D0PUuu
uu:
The pressure units. 00 = PSI, 01 = BAR, 02 = KPA
EXAMPLE:
If the dispenser is set to display units of pressure in KPA, the text packet received from the dispenser is:
(STX) + 06 + 1F + (ETX)
The above text packet in hexadecimal format:
STX
0
6
D
0
P
U
0
2
1
F
ETX
0x02
0x30
0x36
0x44
0x30
0x50
0x55
0x30
0x32
0x31
0x46
0x03
2.6.3.6 Vacuum Units Read Command
This command returns the units the dispenser is using to display vacuum.
Client command and data:
(STX) + 04 + E5-- + E2 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
E
5
space space
E
2
ETX
0x02
0x30
0x34
0x45
0x35
0x20
0x20
0x45
0x32
0x03
NOTE:
“D0” is the letter “D” followed by the digit “0.”
Return Format:
D0VUuu
uu:
The vacuum units. 00 = KPA, 01 = Inches H
2
O, 02 = Inches Hg, 03 = mmHg, 04 = TORR.
EXAMPLE:
If the dispenser is set to display units of vacuum in H
2
O, the text packet received from the dispenser is:
(STX) + 06 + 1A + (ETX)
The above text packet in hexadecimal format:
STX
0
6
D
0
V
U
0
1
1
A
ETX
0x02
0x30
0x36
0x44
0x30
0x56
0x55
0x30
0x31
0x31
0x41
0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
67
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.