2.6.3.10 Real Time Clock Read Command
This command returns the current time of the real time clock on the dispenser.
Client command and data:
(STX) + 04 + EE-- + D2 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
E
E
space space
D
2
ETX
0x02
0x30
0x34
0x45
0x45
0x20
0x20
0x44
0x32
0x03
NOTE:
“D0” is the letter “D” followed by the digit “0.”
Return Format:
D0HhhMmmAMa
hh:
Hours. 0–23 for 24 hour format, 1–12 for 12 hour format
mm:
Minutes. 0–59
a:
Hour format. 0 = AM, 1 = PM, 2 = 24 hour format
EXAMPLE:
If the current time on the dispenser is 14:25, the text packet received from the dispenser is:
(STX) + 0B + D0H14 F9 + (ETX)
The above text packet in hexadecimal format:
STX
0
B
D
0
H
1
4
M
2
5
A
M
2
0x02
0x30
0x42
0x44
0x30
0x48
0x31
0x34
0x4D
0x32
0x35
0x41
0x4D
0x32
F
9
ETX
0x46
0x39
0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
70
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.