2.6.2.22 Set the Real Time Date Command
This command sets the date for the real time clock on the dispenser.
Client command and data:
EC--MmmDddYyy
mm:
Months. 1–12
dd:
Days. 1–31
yy:
Years. 00–99
EXAMPLE:
To set the date as 1st January 2022, the text packet is: (STX) + 0D + EC-- + M01 B4 + (ETX)
Length of this text packet:
Decimal 13 or hexadecimal 0D
The above text packet in hexadecimal format:
STX
0
D
E
C
space space
M
0
1
D
0
1
Y
0x02
0x30
0x44
0x45
0x43
0x20
0x20
0x4D
0x30
0x31
0x44
0x30
0x31
0x59
2
2
B
4
ETX
0x32
0x32
0x42
0x34
0x03
2.6.2.23 Operator Lockout Set Command
This command updates the operator lockout settings. A “1” indicates that a feature is locked out. A “0” indicates
that the feature is not locked out.
Client command and data:
EG--PAppppDTtDPpDVvMmDCcDMdAIaARuALbMMePUfVUgLAhCLjCOkAMn
pppp:
4-digit password. This needs to match the password set on the dispenser. The dispenser returns an error if
incorrect.
t:
Lockout dispense time: “1”=lockout, “0”=enabled (DT)
p:
Lockout dispense pressure (DP)
v:
Lockout dispense vacuum (DV)
m:
Lockout memory cell selection (M)
c:
Lockout deposit counter selection (DC)
d:
Lockout dispense mode change (DM)
a:
Lockout Auto Increment Mode selection (AI)
u:
Lockout Auto Increment Reset (AR)
b:
Lockout Alarms Reset (AL)
e:
Lockout Main Menu selection (MM)
f:
Lockout Pressure Unit Menu selection (PU)
g:
Lockout Vacuum Unit Menu selection (VU)
h:
Lockout Language Menu selection (LA)
j:
Lockout Set Clock / Date Menu selection (CL)
k:
Lockout Set Communications Menu selection (CO)
n:
Lockout Alarm Options Menu selection (AM)
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
60
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.