2. UK (British
3. CUSTOM (defined by user)
IMPORTANT
The reference standard selection can be changed
only if no blast chilling cycle is active, setting the
parameter “nOr”.
(see paragraph H.9
to
activate the parameter)
IMPORTANT
The correct end of cycle temperature and time limits
set by the NF and UK standards are fixed and
cannot be changed by the user, whereas the
CUSTOM standard is configurable.
For example, if the NF setting is used, a positive blast chilling
cycle with core probe ends correctly if the temperature of 10
℃
(50
℉
) is reached within 110 minutes.
Blast chilling then proceeds until the factory-set maintaining
temperature is reached or the user presses STOP. See par.
C.2.2.7 for the procedure for modifying the temperature of the
CUSTOM Standard and par. D.6 for the list of parameters.
SOFT / HARD CHILLING
Standard
Chilling
start tem-
perature
Chilling end
temperature
Chilling
duration
NF
+63
℃
(145.4
℉
)
+10
℃
(50
℉
)
110 minutes
UK
+70
℃
(158
℉
)
+3
℃
(37.4
℉
)
90 minutes
CUSTOM
CbSt
℃
CCEt
℃
CCtI minutes
FREEZING
Standard
Chilling
start tem-
perature
Chilling end
temperature
Chilling
duration
NF
+63
℃
(145.4
℉
)
-18
℃
(64.4
℉
)
270 minutes
UK
+70
℃
(158
℉
)
–18
℃
(-0.4
℉
)
240 minutes
CUSTOM
CbSt
℃
CFEt
℃
CFtI minutes
H
INSTRUCTION FOR THE USER
CAUTION
Before using the machine, clean the
compartment with a detergent solution,
as there may still be residuals of conden-
sation
from
final
testing
by
the
manufacturer
(see
paragraph
Cleaning the cabinet and accessories
for
the type of product to use).
H.1
Switching on
Turn on the protection switch installed upstream of the
appliance and press the ON button to activate it. The ON LED
lights up to signal that the appliance is powered.
H.2
Selecting a standard cycle
The machine default setting is the SOFT chilling cycle.
Use the button
to select
From left to right:
• Positive SOFT chilling
• Positive HARD chilling
• Positive maintaining (or preservation)
• Negative blast chilling or freezing
• Negative maintaining (or preservation)
When selecting the required cycle, press the button
to go
to the next selection; management is circular therefore it is
possible to scroll forwards or back.
If the required cycle is another one, press the button
until
selected and start it with the button
IMPORTANT
The machine automatically recognises when the
core probe is inserted in the product. If the core
probe is not inserted, a timed cycle will start
automatically. It is necessary to wait 2 minutes
after the end of the preparation cycle for automatic
recognition (
see chapter “Analysis of user inter-
face“ in the complete user manual on the web
site
).
Therefore if a timed cycle starts, after 2 minutes the
TIME LED will light up and the COMPARTMENT
TEMPERATURE will be displayed by default.
H.3
Selecting a turbo cooling cycle
• To select the turbo cooling cycle, press the button
;
• the LED
turns orange;
• To start the cycle, press the button
.
H.4
Selecting a programme
The user must firstly decide which type of cycle to start (SOFT,
HARD, etc.) and then select the required programme.
Proceed as follows:
• select the required type of cycle;
• press the programme selection button
;
• the LED
turns orange;
• press the selection button
until the LED of the required
programme
lights up;
If the type of programme is suitable:
• start it by pressing the button
.
Otherwise:
• press the selection button
until the LED of the required
programme
lights up;
• to start the programme, press the button
.