The temperature display can show the compartment temper-
ature and the core probe temperature (if present). If a
cycle is
active
(positive or negative maintaining, timed positive blast
chilling or timed freezing), the temperature displayed is the
compartment temperature (if present). If a
core probe cycle is
active
, the core probe temperature will be displayed by default.
Press the button
in blast chilling cycles to switch between
compartment temperature and core probe temperature (if
present). The LED indicates which of the two temperatures is
being displayed at that time:
• if the core probe temperature is displayed, the
Core probe temperature led lights up
• if the compartment temperature is displayed,
the compartment temperature led lights up.
Only 1 of the 2 is on.
If a cycle is active (positive or negative maintaining, timed
positive blast chilling or timed freezing), the temperature
displayed is the compartment temperature.
G.6
Time
• During a blast chilling cycle: the time display shows the total
or remaining chilling time
• During a maintaining cycle: the display shows the time
• During a turbo cooling cycle: the display shows:
– “°°°°“= approx. 2 hours before defrost start
– “°°°“= approx. 1 ½ hours before defrost start
– “°°“= approx. 1 hour before defrost start
– “°“= approx. ½ hour before defrost start
The Timed cycle led
is on only when a timed blast chilling
cycle is in progress. In the cycle selection phase it indicates the
chilling time.
G.7
UP/Manual defrost button
This is a double function button:
1. INCREASE VALUE: use during modification to increase
the parameter and set point values or to go to the next
parameter;
2. MANUAL DEFROST: if system conditions allow it, press
the button for at least 4 seconds to activate manual
defrost. The message “dEfr“ appears on the display
throughout the entire phase. The selection is valid only in
preservation/maintaining conditions and in the selection of
the operation cycle. At the end of defrost, the board
returns to the main configuration.
G.8
Down/Set button
Use during modification to decrease the parameter and
setpoint values or scroll the parameters back.
G.9
Alarm warning
1.
HACCP/History
For displaying the compartment high temperature alarm
and blast chilling cycle end error alarm.
When an HACCP alarm occurs, the LED:
• blinks if the alarm is in progress.
• stays on (fixed) if the alarm has ended but must still be
seen by the user.
2.
Service alarms
In the SERVICE ALARMS function all the alarms, except
the compartment high temperature alarm and blast chilling
cycle end error alarm are stored and can be displayed .
• blinks if the alarm is in progress.
• stays on (fixed) if the alarm has ended but must still be
seen by the user.
(see chapter J
for all information on alarms)
G.10 Display core probe temperature
(if the core probe is present)
Use this function to display the core probe temperatures if
there is more than one core probe inserted in the product. If
only one core probe is used, to display the temperature refer to
that given in paragraph G.5
.
G.11
Sterilisation cycle
(Function for appliances with germicidal lamp)
The UV lamps have a direct germicidal action and are used to
sterilise the surfaces and air inside the compartment of the
machine (see pararagraph F.4
Sterilisation cycle (function for
appliances with germicidal lamp)
). No cycle must be active.
During the cycle, the “TEMPERATURE” display shows the
compartment temperature. The main menu is shown at the
end of the cycle.
G.12 Food safe control
(if present)
Indicates machine HACCP status. The FOOD SAFE CON-
TROL LED lights up and turns:
RED
• during a blast chilling cycle (timed or with core probe);
• at the end of a core probe blast chilling cycle, if the cycle
does not end correctly;
• uring preservation/maintaining in case of a compartment
high temperature alarm;
• during preservation after blast chilling, if the process does
not end correctly;
GREEN
• at the end of a core probe blast chilling cycle, if the cycle
ends correctly;
• during preservation/maintaining if there are no HACCP
alarms;
OFF
• machine in standby mode;
G.13 Reference standard
G.13.1 Reference standard
The appliance can be set in accordance with 3 different
standards:
1. NF (French)
FOODSAFE
CONTROL