3 Display, operation and options
BU 0240 en-US-4920
49
3 Display, operation and options
Pos: 183 /Anleitungen/El ektr onik/FU und Starter/3. Anzeige, Bedienung und Optionen/Anzeige, Bedienung und Optionen_01 [SK 2xxE] @ 8\m od_1441111756429_14638.docx @ 238818 @ @ 1
In the factory default configuration, without additional options, the diagnostic LEDs are externally
visible. These indicate the actual device status. Two potentiometers (only SK 2x5E) and 8 DIP
switches (S1) are provided in order to set the most important parameters. In this minimum
configuration no other adapted parameters are stored in the external (plug-in) EEPROM. The only
exception is data concerning operating hours, faults and fault circumstances. This data can only be
saved in the external EEPROM (memory module) up to firmware version V1.2. As of firmware version
1.3, this data is saved in the internal EEPROM of the variable frequency drive.
The memory module (external EEPROM) can be pre-parameterized independently of the variable
frequency drive using programming adapter SK EPG-3H.
Figure 5: SK 2xxE (size 1), top view
Figure 6: SK 2xxE (size 1), internal view
No. Designation
SK 2x0E size 1 … 3
SK 2x5E and SK 2x0E size 4
1
Diagnostic opening 1
RJ12 connection
RJ12 connection
2
Diagnostic opening 2
DIP switch AIN
(250
Ω
for current setpoint)
Diagnostic LEDs
3
Diagnostic opening 3
Diagnostic LEDs
Potentiometers (P1/P2)
4
8x DIP switches
5
Plug-in EEPROM
Pos: 184 /Anleitungen/El ektr onik/FU und Starter/3. Anzeige, Bedienung und Optionen/Bedi enung [SK 1xxE, 2xxE, -FDS]/Bedi en- und Param etri erboxen, Verwendung_02_INF ORMATION _Drehm oment [SK 1xxE, SK 2xxE, SK xxxE-FDS] @ 42\m od_1590584836809_14638.docx @ 2628659 @ @ 1
,
Information
Diagnostic caps’ tightening torques
The tightening torque for the transparent diagnostic caps (inspection glasses) is 2.5 Nm.
Pos: 185 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uch kompakt --------- @ 13\m od_1476369695906_0.docx @ 2265496 @ @ 1
Summary of Contents for NORDAC FLEX SK 205E Series
Page 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Page 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Page 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Page 97: ...Key word index BU 0240 en US 4920 97...
Page 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Page 99: ...Key word index BU 0240 en US 4920 99...
Page 100: ...6072403 4920...