4 Commissioning
BU 0240 en-US-4920
59
Details of DIP switch S1: 5/4 and 3
Explanation: (values underlined in brackets) = (relevant parameter/source of function),
e.g.: Parameter (P420[01])
{curly brackets} = {function}
e.g.: {01} "Enable right"
* Default setting
** only if present (devices without "safe stop" function)
*** only with SK 2x5E
Explanation: See table above
Note:
The functions of potentiometers*** P1 and P2 correspond to those of devices without an AS interface (see table above).
With DIP switches 5 and 4 in the OFF position (default setting), the digital inputs are also active. The functions then correspond to those of devices
without an AS interface (table above). In all other DIP switch combinations the functions of the digital inputs are deactivated.
ASi OUT1 and ASi OUT2 loop the signal level (High/Low) of digital inputs 1 and 2.
Pos: 241 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uch kompakt --------- @ 13\m od_1476369695906_0.docx @ 2265496 @ @ 1
Applies to devices SK 20xE, SK 21xE (without on-board AS interface)
DIP
Functions as per the list of digital functions (P420)
Functions as per the list of
analog functions (P400)
5 4 3
Dig 1
Dig 2
Dig 3
Dig 4**
Poti 1***
Poti 2***
off off off
P420 [01]*{01}
"Enable R“
P420 [02]*{02}
"Enable L“
P420 [03]*
{04} "fixed freq 1"
=5 Hz (P465[01])
P420 [04]*
{05} "fixed freq 2"
=10 Hz (P465[02])
P400 [01]*
{01} "F
setpoint"
P400 [02]*
{15} "ramp"
off on off
{01} "Enable R"
{02} "Enable L"
{26} "F
setpoint"***
{12} "Quit"
{05} "F max"
{04} "F min"
on off off
{45} "3-on"
{49} "3-off"
{47} "Freq. +"
{48} "Freq. -"
{05} "F max"
{15} "Ramp"
on on off
{50} "F Arr Bit0"
=5Hz (P465[01])
{51} "F Arr Bit1"
=10 Hz (P465[02])
{52} "F Arr Bit2"
=20 Hz (P465[03])
{53} "F Arr Bit3"
=35 Hz (P465[04])
{05} "F max"
{15} "Ramp"
off off on
The functions of the digital inputs are inactive (control via system bus) but the settings
entered in the parameters (P420 [01 … 04]) for functions designated with ..² in the
function list (e.g.: {11}²= "quick stop") result in the activation of the correspondingly
parameterized input.
P400 [01]
{01} "F
setpoint"
P400 [02]
{15} "ramp"
P420 [01]
no function
P420 [02]
no function
P420 [03]
{04} "fixed freq1"
=5 Hz (P465[01])
P420 [04]
{05} "fixed freq2"
=10 Hz (P465[02])
off on on
{14} "Remote
control"
"Encoder track A" "Encoder track B" {01} "Enable R"
{01} "F
setpoint"
{05} "F max"
on off on
{14} "Remote
control"
{01} "Enable R"
{10} "Block"
{66} "Release
brake"
{01} "F
setpoint"
{05} "F max"
on on on
{14} "Remote
control"
{51} "F Arr Bit1"
=10 Hz (P465[02])
{52} "F Arr Bit2"
=20 Hz (P465[03])
{53} "F Arr Bit3"
=35 Hz (P465[04])
{05} "F max"
{15} "Ramp"
Applies to devices SK 22xE, SK 23xE (without AS interface on board)
DIP
Functions as per the list of digital functions (P420)
Functions as per the list of digital outputs
(P434)
5
4
3
ASi
In1
ASi
In2
ASi
In3
ASi
In4
ASi
Out1
ASi
Out2
ASi
Out3
ASi
Out4
off off off
P480 [01]*{01}
"Enable R“
P480 [02]*{02}
"Enable L“
P480 [03]*{04}
"Fixed freq. 1"
=5 Hz (P465[01])
P480 [04]*{12}
"Quit"
P481 [01]*
{07} "Error"
P481 [02]*
{18} "Ready"
"DigIn1" "DigIn2"
off on off
{04} "Fixed
freq. 1"
=5 Hz
(P465[01])
{05} "Fixed
freq. 2"
=10 Hz
(P465[02])
{06} "Fixed
freq. 3"
=20 Hz
(P465[03])
{07} "Fixed
freq. 4"
=35 Hz
(P465[04])
{07} "Error" {18} "Ready" "DigIn1" "DigIn2"
on off off
{01} "Enable
R"
{02} "Enable
L"
{47} "Freq. +" {48} "Freq. -" {07} "Error" {18} "Ready" "DigIn1" "DigIn2"
on on off
{51} "F Arr B1"
=10 Hz (P465[02])
{52} "F Arr B2"
=20 Hz (P465[03])
{53} "F Arr B3"
=35Hz (P465[04])
{14} "Remote
control"
{07} "Error" {18} "Ready" "DigIn1" "DigIn2"
off off on
The functions of the ASI-In bits are inactive (control via system bus) but
the settings entered in the parameters (P480 [01 … 04]) for functions
designated with ..² in the function list (e.g.: {11}²= "quick stop") result in
the activation of the correspondingly parameterized bit
P481
[01]{07}
"Error"
P481
[02]{18}
"Ready"
"DigIn1" "DigIn2"
P480 [01]
no
function
P480 [02]
no function
P480
[03]
{04}
"Fixed freq.
1"
=5 Hz
(P465[01])
P480 [04]{12}
"Quit"
off on on
{14} "Remote
control"
{04} "Fixed
freq. 1"
=5 Hz
(P465[01])
{05} "Fixed
freq. 2"
=10 Hz
(P465[02])
{06} "Fixed
freq. 3"
=20 Hz
(P465[03])
{07} "Error" {18} "Ready" "DigIn1" "DigIn2"
on off on
{14} "Remote
control"
{01} "Enable
R"
{47} "Freq. +" {48}
"Freq. -"
{07} "Error" {18} "Ready" "DigIn1" "DigIn2"
on on on
{14} "Remote
control"
{50} "F Arr B0"
=5Hz (P465[01])
{51} "F Arr B1"
=10 Hz (P465[02])
{52} "F Arr B2"
=20Hz (P465[03])
{07} "Error" {18} "Ready" "DigIn1" "DigIn2"
Summary of Contents for NORDAC FLEX SK 205E Series
Page 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Page 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Page 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Page 97: ...Key word index BU 0240 en US 4920 97...
Page 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Page 99: ...Key word index BU 0240 en US 4920 99...
Page 100: ...6072403 4920...