E007
7.0
Mains phase failure
Fault on supply connection side
• A power phase is not connected
• Line power is asymmetric
7.1
Phase failure dc-link
DC link voltage too low
• A power phase is not connected
• Load temporarily too high
Pos: 666 /Anleitungen/El ektr onik/FU und Starter/6. M eldung en zum Betriebszustand/Störm eldung en (Auflistung)/F ehl er E007 - Hinw eis [SK 500P, SK 200E(-FDS), SK500E] @ 58\m od_1606138157993_14638.docx @ 2695039 @ @ 1
On 7.1
Devices with external 24 V DC supply of the control
unit:
If the line voltage is switched off, but the control unit is still
supplied with 24 V DC, this error message also occurs.
If the line voltage is switched on again, the error message
must be acknowledged. It is not before until then that the
variable frequency drive can be released.
Pos: 667 /Anleitungen/El ektr onik/FU und Starter/6. M eldung en zum Betriebszustand/Störm eldung en (Auflistung)/F ehl er E008 [SK 2xxE] @ 2\m od_1347453314366_14638.docx @ 46577 @ @ 1
E008
8.0
Parameter loss
(maximum EEPROM value
exceeded)
Error in EEPROM data
• Software version of the stored data set not
compatible with the software version of the VFD.
NOTE:
Faulty parameters are automatically reloaded
(default data).
• EMC interferences (see also E020)
8.1
Inverter ID error, “Inverter
type incorrect”
• EEPROM faulty
8.2
Reserved
8.3
EEPROM KSE error
(Customer unit incorrectly
identified (customer's interface
equipment))
The upgrade level of the variable frequency drive was not
correctly identified.
EEPROM with a firmware status of version 1.2 or above
plugged in to an VFD with older firmware status →
Loss of
parameters!
(also see
Information
in section 5)
• Switch line voltage off and on again.
8.4
Internal EEPROM error
(Database version incorrect)
8.7
EEPROM copy differs, “EEPR
copy not the same”
Pos: 668 /Anleitungen/El ektr onik/FU und Starter/6. M eldung en zum Betriebszustand/Störm eldung en (Auflistung)/F ehl er E009 "reserviert" [SK 180E/SK 2xxE/SK2xxE-FD S] @ 2\m od_1347453797027_14638.docx @ 46702 @ @ 1
E009
---
Reserved
Pos: 669 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uch kompakt --------- @ 13\m od_1476369695906_0.docx @ 2265496 @ @ 1
Summary of Contents for NORDAC FLEX SK 205E Series
Page 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Page 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Page 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Page 97: ...Key word index BU 0240 en US 4920 97...
Page 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Page 99: ...Key word index BU 0240 en US 4920 99...
Page 100: ...6072403 4920...