4 Commissioning
Pos: 222 /Anleitungen/El ektr onik/FU und Starter/1. Allgemei nes/Sicherheits- und Install ationshinw eise und W arn- Gefahrenhinw eise/neu/War n- und Gefahrenhinw eise/WARNUN G - U nerw artete Bew egung [Umrichter] @ 33\mod_1557225504645_14638.docx @ 2533756 @ @ 1
WARNING
Unexpected movement
Connection of the supply voltage may directly or indirectly set the device into motion. This may cause
unexpected movement of the drive and the attached machine, which may result in serious or fatal
injuries and/or material damage. Possible causes of unexpected movements are e.g.:
– Parameterization of an "automatic start"
– Incorrect parameterization
– Control of the device with an enabling signal from a higher level control unit (via I/O or bus
signals)
– Incorrect motor data
– Incorrect encoder connection
– Release of a mechanical holding brake
– External influences such as gravity or other kinetic energy which acts on the drive unit
– In IT systems: System fault (ground fault)
• To avoid any resulting hazard, the drive or drive chain must be secured against unexpected
movements (mechanical blocking and/or decoupling, provision of protection against falling, etc.). In
addition, make sure that there are no persons within the area of action and the danger area of the
system.
Pos: 223 /Anleitungen/El ektr onik/FU und Starter/4. Inbetriebnahm e/SK 1xxE, SK 2xxE, -FD S/W erksei nstellungen/W erksei nstellungen [SK 1xxE, SK 2xxE, FDS] @ 1\mod_1343217972184_14638.docx @ 37257 @ 2 @ 1
4.1 Factory settings
Pos: 224 /Anleitungen/El ektr onik/FU und Starter/4. Inbetriebnahm e/SK 1xxE, SK 2xxE, -FD S/W erksei nstellungen/W erksei nstellungen_01 [SK 1x0E, SK 2xxE, SK 2xxE-FD S] @ 8\mod_1441286953067_14638.docx @ 239677 @ @ 1
All variable frequency drives supplied by Getriebebau NORD are pre-programmed with the default
setting for standard applications with 4 pole standard motors (same voltage and power). When using
motors with another output or number of poles, enter data from the nameplate of the motor in
parameters
P201
...
P207
under the menu item >Motor data<.
All motor data (IE1, IE4) can be pre-set using parameter
P200
. After using this function, this
parameter is reset to 0 = no change! The data is loaded automatically to parameters
P201
...
P209
and
can be compared again with data on the motor nameplate.
3~ Mot
IEC 56
IM B3
cos
j
0,74
cosj 0,74
IP55
Rot. KL 16
Th.Cl.F
EN60034
60 Hz
460 V Y
5,2 A
2,5 kW
1765 /min
1440 /min
P206
P201
P204
P203 P202
P200
9,0 /
5,2 A
50 Hz
2,2 kW
P207
P200 motor list:
0 = No change
8 = 0.37kW 400V
1 = No motor
9 = 0.50HP 460V
2 = 0.25kW 230V
10 = 0.55kW 230V
3 = 0.33HP 230V
11 = 0.75HP 230V
4 = 0.25kW 400V
12 = 0.55kW 400V
5 = 0.33HP 460V
13 = 0.75HP 460V
6 = 0.37kW 230V
14 = 0.75kW 230V
7 = 0.50HP 230V ....
230 /
400 V
D/
Y
Summary of Contents for NORDAC FLEX SK 205E Series
Page 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Page 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Page 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Page 97: ...Key word index BU 0240 en US 4920 97...
Page 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Page 99: ...Key word index BU 0240 en US 4920 99...
Page 100: ...6072403 4920...