Pos: 189 /Anleitungen/El ektr onik/FU und Starter/3. Anzeige, Bedienung und Optionen/Bedi enung [SK 1xxE, 2xxE, -FDS]/Bedi en- und Param etri erboxen, Verwendung_01 [SK 1x0E, SK 2xxE, SK xxxE-FD S] @ 48\mod_1597666648135_14638.docx @ 2663129 @ 35 @ 1
3.1.1 Use of control and parameterization units
All parameters can be conveniently accessed for reading or editing by means of an optional Simple
Box or Parameter Box. The modified parameter data is stored in the non-volatile EEPROM memory.
Up to 5 complete device data sets can be stored in the Parameter Box and then retrieved.
The Simple Box or the Parameter Box is connected to the device through an RJ12-RJ12 cable.
Figure 7: Simple Box, handheld, SK CSX-3H
Figure 8: Parameter Box, handheld, SK PAR-3H
Module
Description
Data
SK CSX-3H
(handheld Simple Box)
Used for commissioning,
parameterization, configuration and
control of the device
1)
.
• 4-digit, 7-segment LED display, membrane
button
• IP20
• RJ12-RJ12 cable
(connection to the device
1)
)
SK PAR-3H
(handheld Parameter Box)
Used for commissioning,
parameterization, configuration and
control of the variable frequency drive and
its options (SK xU4-…). Entire parameter
data sets can be stored.
• 4-line backlit LCD display, membrane keys
• Stores up to 5 complete parameter data
sets
• IP20
• RJ12-RJ12 cable (connection to the
device)
• USB cable
(connection to PC)
1)
Does not apply to optional modules such as bus interfaces
Connection
1. Remove diagnostics glass of the RJ12 socket.
2. Establish RJ12-RJ12 cable connection between
control unit and FEHLER - Variable ohne Inhalt.
When a diagnostics glass or a blind plug is open,
make sure no dirt or moisture enters the device.
3. After commissioning, screw the
diagnostics glass
or blind plugs back in again
and make sure they
are
tightly sealed
before starting regular operation.
Pos: 190 /Anleitungen/El ektr onik/FU und Starter/3. Anzeige, Bedienung und Optionen/Bedi enung [SK 1xxE, 2xxE, -FDS]/Bedi en- und Param etri erboxen, Verwendung_02_INF ORMATION _Drehm oment [SK 1xxE, SK 2xxE, SK xxxE-FDS] @ 42\m od_1590584836809_14638.docx @ 2628659 @ @ 1
,
Information
Diagnostic caps’ tightening torques
The tightening torque for the transparent diagnostic caps (inspection glasses) is 2.5 Nm.
Pos: 191 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uch kompakt --------- @ 13\m od_1476369695906_0.docx @ 2265496 @ @ 1
Summary of Contents for NORDAC FLEX SK 205E Series
Page 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Page 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Page 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Page 97: ...Key word index BU 0240 en US 4920 97...
Page 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Page 99: ...Key word index BU 0240 en US 4920 99...
Page 100: ...6072403 4920...