33
5.
There is an access hole to the sprayer electrical panel on the front right corner.
Route the free end of
C14
to the electrical panel through this hole.
6.
In the electrical panel towards the front of the sprayer, wire the white wire on
C14
to +12V and the black wire to Ground. Each polarity is labeled on the wire.
Refer to
Figure 32
for recom12V and Ground connections inside of the
electrical panel.
NOTE: An automotive GTO fuse may be required for your installation.
NORAC recommends a fuse with a rating of 15 A.
Figure 32 – Power and Ground Connections
7.
Route
R16
of
C10
to the exterior of the cab. There is an access panel located on
the front right corner of the cab floor. It can be removed to allow cables to be
routed to the exterior of the cab. Use this panel to route
R16
through the hole
of the provided access panel plate (
Item B16
) (
Figure 33
).
B16
maintains the
cab seal. Leave the cover plates (
Items B17
and
B18
) unscrewed at this point.
Figure 34
shows the access panel and the installed plates (
B16
,
B17
and
B18
).
C12V
wire here (spade
terminal)
Connect
GROUND wire
here
Summary of Contents for UC4 Total Control
Page 23: ...21 Figure 15 Installation Details ...
Page 30: ...28 Figure 24 General Valve Block Mounting Location Figure 25 Installed NORAC Valve Block ...
Page 41: ...39 5 3 Item C3 44656 Valve Cable Variable Rate 5 4 Item C4 44651 Valve Extension Cable ...
Page 42: ...40 5 5 Item C10 44650 39 Power Cable Generic Self proplelled ...
Page 43: ...41 5 6 Item C11 44651 03 Extension Cable Valve Generic ...
Page 44: ...42 5 7 Item C12 44658 32 Interface Cable ...
Page 45: ...43 5 8 Item C14 44658 28 Interface Cable Power Pigtail ...