19
4.4.2 Mounting on the Boom
Figure 13 – Main Roll Sensor Mounting Locations
1.
When mounting the UC4 main roll sensor and target, first, determine whether
your sprayer will allow the roll sensor to be mounted in front of the boom
(preferred).
NOTE: Sprayers that use parallel links to move the main section usually
allow for the sensor and target to be mounted in front of the
boom. Some sprayers using a vertical main rack system will not
allow them to be mounted in front of the boom.
2.
Determine a proper mounting location for the main roll sensor and target.
Following are
General Mounting Rules
for the sensor and target, and the
details are shown in
Figure 14
and
Figure 15
:
•
The sensor must have a 12-inch diameter clear view of the ground without
any obstructions (e.g. Nozzles, Hoses, Fenders).
•
The sensor and target are to be mounted as far outward from the center of
the boom as possible (See FRONT VIEW of
Figure 15
).
•
The sensor and target are to be mounted as low as possible while maintaining
the height requirements as shown in
Figure 14
.
•
The bottom of the sensor should be between 18" to 22" above the target as
shown in
Figure 14
.
•
Ensure that there will be no contact between the sensor/target and the booms
when folding and unfolding.
Summary of Contents for UC4 Total Control
Page 23: ...21 Figure 15 Installation Details ...
Page 30: ...28 Figure 24 General Valve Block Mounting Location Figure 25 Installed NORAC Valve Block ...
Page 41: ...39 5 3 Item C3 44656 Valve Cable Variable Rate 5 4 Item C4 44651 Valve Extension Cable ...
Page 42: ...40 5 5 Item C10 44650 39 Power Cable Generic Self proplelled ...
Page 43: ...41 5 6 Item C11 44651 03 Extension Cable Valve Generic ...
Page 44: ...42 5 7 Item C12 44658 32 Interface Cable ...
Page 45: ...43 5 8 Item C14 44658 28 Interface Cable Power Pigtail ...