Instructions Manual
67
If there is a difference, the distance indicated in fig.145 can be adjusted as
described below.
With the power socket of the tractor disconnected:
1- Loosen the nut A (fig.146).
2- With a hammer, carefully hit the end of the shaft (on the side of the worm),
moving the shaft and the pinion upwards.
3- Turn the disk to obtain the adjustment indicated in fig.145.
4- After adjusting the disk, hit the end of the shaft (on the pinion side) to move
it back to the original position. Retighten the nut A.
A
WORM
DISK
PINION
SHAFT
fig.146
ADJUSTMENT OF THE RETAINING DISK
The retaining disk has four rabbets where the cord goes. These rabbets must
be correctly positioned. If the cord does not touch the rabbet, it will not be
caught between the retaining clamp and disk and will not be able to be cut by
the blade. In order to function perfectly, the measure indicated in fig.145 must
be 0 through 2 mm.
IMPORTANT: This verification must be done with the cord caught in the disks.
0 a 2 mm
fig.145
RETAINING
CLAMP
RETAINING
CLAMP
fig.144
Summary of Contents for EXPRESS-5040
Page 1: ......
Page 2: ......
Page 18: ...18 Instructions Manual SECTION A CONNECTION ...
Page 22: ...22 Instructions Manual SECTION B PREPARATION AND OPERATION ...
Page 36: ...36 Instructions Manual SECTION C MAINTENANCE AND LUBRICATION ...
Page 37: ...Instructions Manual 37 PERIODIC MAINTENANCE TABLE ...
Page 77: ...Instructions Manual 77 SECTION D PRACTICAL GUIDE ...
Page 86: ...86 Instructions Manual SECTION E TECHNICAL FEATURES ...
Page 104: ...16 Manual de Instrucciones SECCIÓN A ACOPLAMIENTO ...
Page 108: ...20 Manual de Instrucciones SECCIÓN B PREPARACIÓN Y OPERACIÓN ...
Page 122: ...34 Manual de Instrucciones SECCIÓN C MANTENIMIENTO Y LUBRICACIÓN ...
Page 163: ...Manual de Instrucciones 75 SECCIÓN D GUÍA PRÁCTICO ...
Page 165: ...Manual de Instrucciones 77 SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 166: ...78 Manual de Instrucciones SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 167: ...Manual de Instrucciones 79 SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 168: ...80 Manual de Instrucciones SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 169: ...Manual de Instrucciones 81 SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 170: ...82 Manual de Instrucciones SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 172: ...84 Manual de Instrucciones SECCIÓN E CARACTERÍSTICAS TÉCNICAS ...
Page 175: ......
Page 176: ...4071022 Revisão 3 ...