Instructions Manual
53
With the needles placed in the highest
point, the measure B must be from 135
to 140mm (picture 88).
Measure B = Distance from the needle
tip from the disk = 135 to 140mm.
NEEDLE
DISC
B
IMPORTANT!
After the adjustment described above, you must observe the synchronism be-
tween the needles and the piston, according to the item “REGULATING NEEDLES
WITH THE PISTON” in this manual.
P
V
fig. 89
R
S
fig. 90
3 – remove the side shield V.
4 – Loosen the safety bolt P (picture 89).
5 – Loosen the adjusting lock nut R (picture 90).
6 - Adjust the movement of the needles through the spindle S.
7 – Retighten the lock nut R and the safety bolt P.
fig. 88
Summary of Contents for EXPRESS-5040
Page 1: ......
Page 2: ......
Page 18: ...18 Instructions Manual SECTION A CONNECTION ...
Page 22: ...22 Instructions Manual SECTION B PREPARATION AND OPERATION ...
Page 36: ...36 Instructions Manual SECTION C MAINTENANCE AND LUBRICATION ...
Page 37: ...Instructions Manual 37 PERIODIC MAINTENANCE TABLE ...
Page 77: ...Instructions Manual 77 SECTION D PRACTICAL GUIDE ...
Page 86: ...86 Instructions Manual SECTION E TECHNICAL FEATURES ...
Page 104: ...16 Manual de Instrucciones SECCIÓN A ACOPLAMIENTO ...
Page 108: ...20 Manual de Instrucciones SECCIÓN B PREPARACIÓN Y OPERACIÓN ...
Page 122: ...34 Manual de Instrucciones SECCIÓN C MANTENIMIENTO Y LUBRICACIÓN ...
Page 163: ...Manual de Instrucciones 75 SECCIÓN D GUÍA PRÁCTICO ...
Page 165: ...Manual de Instrucciones 77 SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 166: ...78 Manual de Instrucciones SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 167: ...Manual de Instrucciones 79 SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 168: ...80 Manual de Instrucciones SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 169: ...Manual de Instrucciones 81 SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 170: ...82 Manual de Instrucciones SÍNTOMA CAUSA PROCEDIMIENTO ...
Page 172: ...84 Manual de Instrucciones SECCIÓN E CARACTERÍSTICAS TÉCNICAS ...
Page 175: ......
Page 176: ...4071022 Revisão 3 ...