Chapter
3: Web Management
Security - AAA - RADIUS Overview
PoE Switch User Manual | 251
IP Address
The IP address and UDP port number (in <IP Address>:<UDP Port> notation) of this
server.
Status
The current status of the server. This field takes one of the following values:
Disabled:
The server is disabled.
Not Ready:
The server is enabled, but IP communication is not yet up and running.
Ready:
The server is enabled, IP communication is up and running, and the RADIUS
module is ready to accept accounting attempts.
Dead (X seconds left):
Accounting attempts were made to this server, but it did not
reply within the configured timeout. The server has temporarily been disabled, but will
get re-enabled when the dead-time expires. The number of seconds left before this
occurs is displayed in parentheses. This state is only reachable when more than one
server is enabled.
Buttons
Auto-refresh:
Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Refresh:
Click to refresh the page immediately.