57
EN
LCD display list
LCD display
Details
Reference
BACK LIGHT
LCD back light
p. 34
BZ-VOLUME
(Buzzer Volume)
Buzzer sound volume
p. 34
C-AUTO
(Continue Auto)
Setting to determine as screw fastening operations OK if all operations channels are
implemented and completed in sequence
p. 25
C-F
(Count Finish)
Setting to output OK signal at time the screw fastening operations are completed
p. 33
CH1
CH2
CH3
CH4
(Channel)
The folder in which the settings are saved
—
CH-CHG
(Channel Change)
Operations channel switching method
p. 25
CHECK-BZ
(Check Buzzer)
Check buzzer sound
p. 34
COUNT
Screw count
p. 31
COUNT UP-BZ
(Count-up Buzzer)
Count-up (normal torque-up) buzzer sound
p. 30
COUNT-FNC
(Count Function)
Count function
p. 31
COUNT-RTN
(Count Return)
Count return (return to screw fastening count number) function
p. 33
CRT-T
(Correct Timer)
Screw fastening time judgment function
Count up the screw fastening within the upper and lower limit setting values
p. 32
CRT-T-L
(Correct Timer Lower)
Screw fastening time lower limit value
Screw fastening NG (count not performed) for screw tightening shorter than the setting
value
p. 32
CRT-T-U
(Correct Timer Upper)
Screw fastening time upper limit value
Screw fastening NG (count not performed) for screw tightening longer than the setting
value
p. 32
DIS
(Disable)
Setting value when CRT-T-U (screw fastening upper limit value) function is set to invalid
p. 32
FSTN-NG-BZ
(Fastening NG Buzzer)
Fastening NG buzzer sound
p. 30
FSTN-T
(Fastening Timer)
Fastening timer
Fastening time setting value at setting speed when at the HARD fastening mode setting
p. 28
FSTN-TYPE
(Fastening Type)
Setting of fastening type, “SOFT” and “HARD”
p. 26
HARD
HARD fastening mode
p. 26
INPUT
Setting to call the specified channel (setting) using input signal channel A/B
p. 25
MEAS-T
Fastening time measurement value at constant low speed, for calculating the fastening
timer setting reference value “RET-T”
p. 28
NG-BZ
(NG Buzzer)
Operations NG buzzer sound
p. 33
OK-BZ
(OK Buzzer)
Operations OK buzzer sound
p. 33
OK-OUT-T
(OK Out Timer)
Screw fastening confirmation time
Possible time for reverse rotation action confirming the screw fastening operation after
screw tightening up to the set count number (time until OK is output)
p. 33
OK-TIMING
OK output timing
Timing setting for outputting the OK signal
p. 33
RATE
Rate for calculating the fastening timer setting reference value “REF-T”
p. 28
REF-T
Fastening timer setting reference value
p. 28
TV07783-1_DLV10C_en.indb 57