- FORM NO. 56043126 - CR 1100, CR 1200
SWEEPING SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Side broom lift actuator will not lower.
Note: Do all testing with key switch on, main broom lever lowered (press the side broom lower button on the A2 display panel if side brooms are
not programmed to lower automatically).
Check for a 36V at the
motor harness plug.
Repair or replace wiring to
motor. Does the motor operate?
Replace lift motor
Side broom(s) will not lower
On the A1 board does the
green side broom lift
indicator light stay on
while motor is extending
Replace the A1 main controller.
Does the side broom(s) run?
At the A2 display panel is
the side broom increase
light on?
Substitute an A2 display panel.
Does the side broom(s) work?
no
no
no
no
no
no
yes
yes
yes