FORM NO. 56043126 - CR 1100, CR 1200 -
65
PROGRAMMABLE CONTROL OPTIONS
Recall Of Stored Error Codes:
Whenever an electrical system fault is detected by the main control unit, one or more error codes are displayed and stored by the control unit. If it
is desired, the error code (if any) from the previous operation of the machine can be recalled for troubleshooting purposes. To recall the last stored
error codes perform the following steps:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
solution switch
.
3
While holding the solution switch, turn the
main power key switch
to the
on
position.
4
Continue to hold the solution switch until all indicators except the solution indicator turn off (approximately two seconds).
5
Release the solution switch.
6
If there were previously no error codes stored, the display will now show “-”. Go to step 10.
7
If error codes were stored, the display will now show the stored code(s). An example of how two codes, 6 and 18, would be displayed is as
follows:
•
The display will show “E” followed by a brief blank period
•
The display will show “0” followed by a brief blank period
•
The display will show “6” followed by a slightly longer blank period
•
The display will show “E” followed by a brief blank period
•
The display will show “1” followed by a brief blank period
•
The display will show “8” followed by a long blank period
•
The above sequence will repeat
8
To clear the stored codes press and release the
solution
switch. The display will now show “-“. Go to step 10.
9
If it is desired to save the codes, go to step 10.
10
To exit the error code recall mode, turn the
main power key switch
to the
off
position.
Reset of All Programmable Parameters to Factory Default Settings:
To reset all of the above parameters to the factory defaults, perform the following steps:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
all three scrub system switches
(scrub off, pressure increase, & pressure decrease).
3
While holding all three switches turn the
main power key switch
to the
on
position.
4
Continue to hold all three switches until all indicators turn off and the status display shows “d” (approximately two seconds).
5
Release all switches.
6
The programmable parameters are now restored to the default values.
7
To exit this mode, turn the
main power key switch
to the
off
position.
Reset of Hourmeters to Zero:
To reset all hourmeters to zero:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
scrub pressure increase, scrub pressure decrease, and solution switches
.
3
While holding all three switches turn the
main power key switch
to the
on
position.
4
Continue to hold all three switches until all indicators turn off and the status display shows “d” (approximately two seconds).
5
Release all switches.
6
The hourmeters are now reset to zero.
7
To exit this mode, turn the
main power key switch
to the
off
position.