18
- FORM NO. 56043126 - CR 1100, CR 1200
IMPORTANT SERVICE TIP
Before any troubleshooting is done perform this troubleshooting special control system procedure.
MAIN CONTROLLER (A1) SELF-DIAGNOSTIC TEST MODE
If problems with the main electronic control system are suspected, this self-diagnostic mode may help isolate the problem. When this mode is
activated, the control unit will activate each one of the outputs in sequence and test for short circuits, open circuits, or overload conditions. This
mode will also provide an easy test for the touch panel switches and indicators.
If an abnormal condition is encountered with one of the outputs, an error code will be displayed on the Scrub Pressure Display
(J)
see Figure 2.
1
During this test, the horn will sound brie
fl
y and the scrub deck and squeegee will move if they are in the up position. If the hopper is not in the
down position it will also move slightly.
CAUTION!
Make sure that all persons are away from these parts of the machine to prevent injury.
2
Turn
the
main power key switch
to the
off
position.
3
Press and hold the
side broom down/on switch
.
4
While holding the side broom down/on switch, turn the
main power key switch
to the
on
position.
5
Continue to hold the side broom down/on switch until all indicators except the side broom down/on indicator turn off (approximately two
seconds).
6
Release the side broom down/on switch.
7
The control will now activate each output in sequence and perform the tests mentioned above.
8
If no abnormal conditions are detected, the display will now show “-”. Go to step 10.
9
If abnormal output conditions were detected, the display will now show the error code(s), see “Main Control Error Code Display Descriptions
Table”. An example of how two codes, 6 and 18, would be displayed is as follows:
•
The display will show “E” followed by a brief blank period
•
The display will show “0” followed by a brief blank period
•
The display will show “6” followed by a slightly longer blank period
•
The display will show “E” followed by a brief blank period
•
The display will show “1” followed by a brief blank period
•
The display will show “8” followed by a long blank period
•
The above sequence will repeat
10
To test any of the control panel switches, press the desired switch. The indicator for that switch should illuminate. If not, consult the general
machine troubleshooting section of this manual which will show machine system
fl
ow charts.
11
The hopper limit, main broom, recovery tank full, and solution tank empty switches may also be tested in this mode. The corresponding
indicators will indicate the state of each of the inputs.
12
To exit this mode, turn the
main power key switch
to the
off
position.
NOTE: If the machine is not equipped with an optional back-up alarm, an error code 59 will be indicated.
KNOW YOUR MACHINE
FIGURE 2
J
Summary of Contents for Cr 1100
Page 72: ......