FORM NO. 56043126 - CR 1100, CR 1200 -
63
PROGRAMMABLE CONTROL OPTIONS
Solution Flow in Reverse Enable/Disable:
FACTORY DEFAULT: 0 (solution
fl
ow off in reverse)
RANGE: 0 - 1
The solution
fl
ow is programmed to stop when backing up to prevent excessive cleaning solution from being dispensed. If it is desired to allow
solution
fl
ow in reverse, perform the following steps:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
solution and the scrub system off switches
.
3
While holding both switches turn the
main power key switch
to the
on
position.
4
Continue to hold both switches until all indicators except the solution and scrub off indicators turn off (approximately two seconds).
5
Release both switches.
6
The status display will now show a 0 or a 1. Pressing and releasing the
solution switch
will alternate between the two. If 0 is selected, solution
fl
ow will stop when backing up. If 1 is selected, solution
fl
ow will stay on when backing up.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.
High Speed Scrub/Sweep (Fast/Slow Switch) Enable/Disable:
FACTORY DEFAULT: 1
RANGE: 0 - 1
Normally, the maximum travel speed is reduced during scrubbing and/or sweeping operations. The fast/slow switch on the control panel allows the
operator to override this speed reduction which allows scrubbing and/or sweeping at maximum speed. If this is not desirable, this feature can be
disabled. This will prevent traveling at maximum speed while scrubbing and/or sweeping. Note: see programming of reduced speed mode to select
speed reduction while scrubbing and/or sweeping. To enable or disable this feature, perform the following steps:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
fast/slow switch
.
3
While holding the fast/slow switch turn the
main power key switch
to the
on
position.
4
Continue to hold the fast/slow switch until all indicators except the fast/slow indicator turn off (approximately two seconds).
5
Release the fast/slow switch.
6
The status display will now show a 0 or a 1. Pressing and releasing the
fast/slow switch
will alternate between the two. If 0 is selected, high
speed scrubbing/sweeping will not be allowed. If 1 is selected, high speed scrubbing/sweeping will be allowed.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.
Reduced Speed Mode:
FACTORY DEFAULT: 1 (reduced speed while scrubbing)
RANGE: 1 - 3
The CR 1100/1200 can be programmed to automatically limit the maximum travel speed while scrubbing only, sweeping only, or either scrubbing or
sweeping. To select which operation will cause the automatic speed reduction, perform the following steps:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
fast/slow and the scrub system off switches
.
3
While holding both switches turn the
main power key switch
to the
on
position.
4
Continue to hold both switches until all indicators except the fast/slow and scrub off indicators turn off (approximately two seconds).
5
Release both switches.
6
The status display will now show a number from 1 to 3. Pressing and releasing the
fast/slow switch
will increase the displayed value until
3 is reached. The next press will return to 1. If 1 is selected, the maximum travel speed will be reduced while scrubbing. If 2 is selected, the
maximum travel speed will be reduced when scrubbing or sweeping. If 3 is selected, the maximum travel speed will be reduced when sweeping
only.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.