FORM NO. 56043126 - CR 1100, CR 1200 -
55
SCRUB SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Scrub deck motors will not operate.
Part A:
Note: Do all testing with the key switch on, seat switch closed, scrub deck pressure set on (1) foot pedal activated and solution shut off.
Scrub deck motors will not operate
Press scrub decrease switch(-) On the
display, is its green indicator light on?
Substitute a new A2 display panel.
Do the motors operate?
Replace A1 control board.
Do the motors operate?
Do any of the brush motors run?
See Brush motor load section
Do other auto drive functions work?
See machine drive auto
function do not work section
Press the scrub increase switch along with
moving the foot pedal. Are the numbers 1, 2
and 3 green scrub lights on at the A1 board?
Left brush does not run.
Check for 36V at K1 brush motor
coil. Wires (+)VIO & (-)YEL/BLU
Repair or replace coil
wiring.
Does the motor run?
Check coil resistance
(120 ohms) + or -
10%
Repair or replace
contactor. Does
scrub motor
operate?
See Part B Load Circuit
Right brush does not run.
Check for 36V at K3 brush motor
coil. Wires (+)VIO & (-)GRA/RED
Center brush does not run.
Check for 36V at K2 brush motor
coil. Wires (+)VIO & (-)WHT/VIO
no
no
no
no
no
no
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no