FORM NO. 56043126 - CR 1100, CR 1200 -
37
HYDRAULIC SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Hydraulic pump motor will not operate.
Part B: Load Circuit
Note: Do all testing with the key switch on and hopper raise button pressed at A2 Display panel.
At the K11 solenoid load wire
ORN/WHT (+ battery input)
check for 36V to battery ground.
Repair or replace defective
wire. Does the pump operate?
Repair or replace pump motor
Replace K11 solenoid.
Does the pump operate?
At the K11 solenoid load wire
(+) output to pump motor check
for 36V to battery ground.
Check for 36V at pump motor
negative input from battery
ground.
Repair or replace defective
wire from battery ground.
Does the pump operate?
Hydraulic pump motor will not
operate
yes
yes
yes
no
no
no
no
no
no