251
Service Manual – SW5500, FLOORTEC R 985
50 - Dust Control System
Vacuum Fan Motor Current Draw Check
WARNING:
This procedure must be performed by qualified personnel only.
1
Drive the machine on a level floor.
2 Turn the ignition key to “0”, then engage the parking brake
3 Unscrew the four screws (A) fastening the fairing (B)
4 Unscrew the nut (C) on the front
5
Slide the sleeve (D) until it is flush on the steering wheel.
6 Press the stud (E), sliding it upwards (causing the Main Control Board (F) to lift slightly, then remove
the fairing (B) by disengaging it from its seat and the stud (E)
7 Position a suitable lifting device (G) at the centre of the front section of the machine, on chassis bracket
(H), then raise the front of the machine by a few centimeters until the driving wheel can turn without
brushing the ground
8 For safety purposes, to prevent accidental lowering of the machine, apply two suitable spacers under the
right (I) and left (J) side brackets
Figure 6:
A
B
A
F
D
C
E
G
H
I
J