Field Station NPL-632 Instruction Manual
107
Menu Key
5
To enter P1 and P2, enter point names or take
measurements to targets.
Enter the plus-minus angle, horizontal distance, and
vertical distance from the baseline defined by P1-P2.
If you do not enter a value in the dVD field, the value
0.0000 is used.
When you press
[ENT]
in the dVD field, a new point is
calculated. The PT name defaults to the last recorded
PT + 1.
To record the new point and return to the point input
screen, press
[ENT]
.
P1 (base PT) defaults to the previously recorded PT. P2
defaults to the previous P1.
Entering coordinates
To manually enter the XYZ coordinates, press
[3]
or
select
Input XYZ
in the Input menu.
The PT name defaults to the last recorded PT + 1.
Enter the coordinates using the numeric keys. To move
to the next field, press
[ENT]
or
[v]
in a field
To store the point as an MP record and return to the
point input screen, press
[ENT]
in the Z field. The default
PT is incremented to the next value.
To continuously calculate a new point, enter +Ang, HD, and dVD from the previous bearing line. This is a
convenient way to enter Traverse points.
You can record NE, NEZ, or Z-only data to the database.
Summary of Contents for NPL-632
Page 1: ...Version A1 1 0 May 2006 Field Station NPL 632 Instruction Manual ...
Page 8: ...Contents viii Field Station NPL 632 Instruction Manual ...
Page 14: ...Safety 16 Field Station NPL 632 Instruction Manual ...
Page 110: ...4 Applications 96 Field Station NPL 632 Instruction Manual ...
Page 168: ...6 Checking and Adjustment 154 Field Station NPL 632 Instruction Manual ...
Page 180: ...8 System Diagrams 166 Field Station NPL 632 Instruction Manual ...
Page 196: ...9 Communications 182 Field Station NPL 632 Instruction Manual ...
Page 206: ...10 Error Messages 192 Field Station NPL 632 Instruction Manual ...