Field Station NPL-632 Instruction Manual
81
Applications
4
The distance from the station point to the first
point appears.
3.
Sight the second point and press
[MSR1]
or
[MSR2]
.
The distances between the first and second point
are displayed
4.
To change display screens, press
[DSP]
.
5.
To record the distance and angle information as
a comment record, press
[ENT]
in the 1/2 or 2/2
observation screen.
Default point numbers are displayed. You can
change these point numbers. To record a note,
press
[ENT]
in the To field.
rSD
Slope distance between two points
rVD
rVD Vertical distance between two points
rHD
rHD Horizontal distance between two
points
rAZ
Azimuth from first point to second point
rV%
Percentage of grade (rVD/rHD) × 100%
rGD
rGD Vertical grade (rHD/rVD): 1
Data that you save in RDM functions is stored in RM records. For more information, see
.
When you download data in Nikon RAW format, they are output as comment (CO) records.