Nikon N Series/K Series Total Station Instruction Manual
107
Menu Key
5
Press OK or
[ENT]
to input the end point.
5.
The information on the end point of the traverse
measurement is displayed.
If the end point has no coordinate data, the
window on the right will be displayed. Select
[Yes] and enter the coordinates of end point. In
case of closed-loop traverse, FS also needs to be
the known point.
Press
[ENT]
in the AZ field to proceed to the
calculation result display of the traverse measurement.
6.
The closure error and precision of traverse
measurement are displayed.
Press the
Sett
soft key to specify the method
for distributing the error.
* Method for coordinate error distribution
7.
Press the
Adjust
soft key or
[ENT]
, and the value
with angular error allocated is displayed.
dHA:
Angular closure error
dHD:
Horizontal closure distance
Prec:
Precision of the traverse
Denominator of the ratio of linear misclosure
divided by the traverse total length.
dN:
N coordinate closure distance
dE:
E coordinate closure distance
dZ:
Z coordinate closure distance
Setting Item
Selection Item
Method*
Compass/Transit
Angular
Weighted/Linear/None
Elevation
Weighted/Linear/None
Summary of Contents for K Series
Page 2: ......
Page 12: ...Safety xii Nikon N Series K Series Total Station Instruction Manual ...
Page 18: ...Contents xviii Nikon N Series K Series Total Station Instruction Manual ...
Page 70: ...3 Getting Started 52 Nikon N Series K Series Total Station Instruction Manual ...
Page 162: ...5 Menu Key 144 Nikon N Series K Series Total Station Instruction Manual ...
Page 168: ...6 Checking and Adjustment 150 Nikon N Series K Series Total Station Instruction Manual ...
Page 172: ...7 System Diagrams 154 Nikon N Series K Series Total Station Instruction Manual ...
Page 188: ...8 Communications 170 Nikon N Series K Series Total Station Instruction Manual ...