14
7.1) Maintenance
The automation must undergo maintenance work on a regular basis,
in order to guarantee prolonged lifetime.
The maintenance operations must be performed in strict
compliance with the safety directions provided in this manual
and according to the applicable legislation and standards.
If other devices are present, follow the directions provided in the cor-
responding maintenance schedule differents from
A60
.
1.
Is requires scheduled maintenance work every 6 months or
10.000 manoeuvres (max.) after previous maintenance.
2.
Disconnect all power supplies.
3.
Check for any deterioration of the components which form the
automation, paying particular attention to erosion or oxidation
of the structural parts. Replace any parts which are below the
required standard.
4.
Connect the electric power sources up again, and carry out the
testing and checks stated in Paragraph “6 Testing”.
!
This charter provides information about how to draw up a maintenance schedule, and the disposal of A60.
7) Maintenance and Disposal
7.2) Disposal
As in the case of installation, at the end of the product lifetime,
disposal procedures must be carried out by qualified personnel.
This product comprises various types of materials, some of which
can be recycled while others must be disposed of. Check informa-
tion on the recycling and disposal procedures according to local
legislation for this product category.
!
Some parts of the product may contain pollutant or hazar-
dous substances; if disposed of into the environment these
may constitute a serious risk of damage to the environment
and public health.
As indicated by the symbol in figure
never dispose of this product in dome-
stic waste. Apply “classified waste col-
lection” procedures for disposal in accor-
dance with local regulations or return the
product to the retailer when purchasing
a new model.
Local regulations may envisage serious fines in the event of illegal
disposal of this product.
RADIO card
The control unit features a connector for plugging in an SM radio
card , which activates the inputs and allows the control unit to be
remote-controlled through a transmitter.
output 1 STEP-BY-STEP
output 2 Open for pedestrians
output 3 Open
output 4 Close
8) Accessories
With the aim of improving products, Nice S.p.a reserves the right to modify technical characteristics at any time without notice, while main-
taining the same functionalities and intended use.
All technical characteristics stated refer to an ambient temperature of 20°C (±5°C).
9) Technical characteristics
Model type:
A60
A60/V1
Power
230 Vac ± 10%, 50 - 60 Hz
120 Vac ± 10%, 50 - 60 Hz
Maximum actuators power
300 W [1,3 A]
300 W [2,5 A]
Maximum flashing light power
100W
Maximum frequency of operating cycles
unlimited
Maximum time of continuous operation
unlimited
Maximun current accessories (24 Vac)
200 mA
Maximun current phototest output
75 mA
Gate open indicator max. power SCA (24Vac)
2 W
Maximun electric lock power 12 Vac
15 VA
Working time
from 2,5 to 40 sec. (from 40 to 80 sec. with TLM)
Pause time
from 5 to 80 sec.
TRA opening delay time
0 or from 2.5 to 12 sec.
TRC closing delay time
0 or from 2.5 to 12 sec.
BALANCING manoeuvre times
from 0 to 8 sec.
Force adjustment
from 0 to 100 %
Operating temperature
-20 ÷ 50 °C
Size
280 x 220 x 110 mm
Weight
1,9 kg
Protection level
IP 55 (container undamaged)
EN