After programming the sensor inputs in the installer menu or during initial startup, the appropriate type
and number of sensors will need to be connected. Figure 73 below shows the wiring and dip switch
settings of an EMX-MON photo eye (typical thru-beam wiring). A retrore
fl
ective photo eye will be similar
and only have wiring similar to the receiver of the thru-beam photo eye.
Figure 73. EMX-MON Photo Eye Wiring
An Edge Sensor can be either hardwired through an adapter module (Hy2NC) or a wireless transmitter/
receiver combo (WEL-200 or iGAZE RE). Figure 74 below shows the wiring and dip switch settings of a
WEL-200. For more information and wiring diagrams of other recommended sensors see the “HySecurity
External Entrapment Sensor Wiring Guide”.
Figure 74. WEL-200 or iGAZE RE
EMX IRB MON
Photo Eye
Receiver
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes.
The sensor becomes actively powered when the
gate operator's motor runs.
CAUTION
CAUTION
CAUTION
CAUTION
Connect all contact and non-contact sensors to same power
source. Example, Do NOT connect photo eyes to +24VDC
and gate edges to +12VDC. Incompatible electricity flow. A
FAULT 2 will appear.
EMX IRB MON
Photo Eye
Transmitter
Set DIP
Switches
1 = OFF
2 = OFF
3 = OFF
4 = ON
NOTE:
DIP switches
mustbe set as shown
otherwise the photo
eye will not operate
correctly.
Jumper POWER INPUT
- 24V to COM in Receiver
COMMON / NEG. to SENSOR COM
RED
NC RELAY to SENSOR 1
+24V
COMMON / NEG. to SENSOR COM
RED
+24V
BLACK
WHITE
BLACK
DIP switches must be set as shown otherwise the photo eye will not operate correctly. If you receive an Alert,
"!ACTION BLOCKED" "Photo Eye Open" PEO or "Photo Eye Close" PEC, take steps to align the photo eye.
SENSOR 1,2, or 3
SENSOR COM
SENSOR COM
+24V
EMX WEL-200 Wireless Edge Receiver
Dip Switch Settings determine which relay
activates when the associated edge is tripped.