This section of the manual provides information
which may be useful when installing SlideSmart
operators. It includes how to:
Connect a Radio Receiver for Remote Open
Install a Gate Locking Mechanism
Install Vehicle Detectors and Loops
Install Photoelectric Sensors
Install Gate Edge Sensors
Troubleshoot error codes, faults, and hardware
issues
Diagnose vehicle detector and loop faults
Handle General Maintenance issues
CONNECTING A RADIO RECEIVER FOR
REMOTE OPEN
Take the following steps to mount a commercial
style 24VDC radio receiver (external antenna type):
1.
Install the receiver in the channel of the chassis
on either side of the control box.
2.
Route the wires to the area marked RADIO
OPTIONS. Only three wire connections are
needed because the common wire and one
radio output wire are connected together.
Figure 65 shows additional wires from a two
channel receiver.
3.
Make sure to observe polarity and crimp
together the black radio common wire and
one of the radio output wires using a ¼-inch
spade connector.
4.
Fasten the two crimped wires to the COM
terminal.
5.
Connect the red wire to the +24V spade and
connect the other radio output contact wire to
the spade marked OPEN.
NOTICE
This terminal is the same as the input terminal
labeled RADIO OPEN along the left edge of
the Smart DC Controller.
ACCESSORY CONNECTIONS
6.
Mount an external antenna onto the top of a
fi
xed fence post near the operator.
7.
Connect the antenna into the socket on the
radio receiver.
8.
Set the “DIP” switches in the receiver to match
the same code used in the transmitter.
Figure 65. Radio Receiver Connections
INSTALLING A MAGLOCK OR SOLENOID
LOCK
To provide additional gate security, a maglock or
a solenoid lock can be used and connected to
the Smart DC Controller. The Smart DC Controller
releases the lock prior to initiating gate movement.
Before installing the lock, be sure to:
Determine the electrical power requirements of
your lock (maglock or solenoid lock). Electronic
board and peripheral connections differ
between high voltage and lower voltage gate
operators.
Determine the current required. Up to 1A is
available from the 24VDC, or 12VDC power
supply. If the peripherals attached to the
terminals need more than 1A, a separate power
supply is required. Refer to "Overview Of The
Smart DC Controller" on page 72and Figure
57.
DUAL GATE
COM
COM
A
B
RADIO OPTI
ONS
OPEN +24V
S1
SENSOR 1
SENSOR
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
U
SE
R2
COM NO
DC
Two Channel Radio Receiver
Power
Shows connecons
for Remote Open
and Gate Edge (dashed line).
R1
MX4505 Rev. E ©2020
SlideSmart DC Programming and Operations
hysecurity.com | 800-321-9947
87