Table 10. Smart DC Controller - Installer Menu Functions
Ref.
No.
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
DC Controller
Display
Connections
14
SS 0 (OFF)
IES STOP ONLY
0 = stop,
reverse for 2s
1 = stop only
In a Usage Class 4 environment,
operator can be set to stop gate
and not reverse gate travel after
an IES trip.
(N/A)
15
LC 0 (0.0 SECS)
LEAF DELAY CLOSE
0 = no delay
1 through 20
in ½ second
increments
For example:
1 = ½ second
10 = 5 seconds
20 = 10 seconds
Only appears if the gate operator
is set up as a Master or a Slave.
Available settings are 1 through
20. Each increment adds ½ second
time delay following a command to
close before the operator activates.
Provides up to a 10 second time
delay.
DUAL GATE inputs
on both operators
16
LO 0 (0.0 SECS)
LEAF DELAY OPEN
0 = no delay
1 through 20
in ½ second
increments
For example:
1 = ½ second
10 = 5 seconds
20 = 10 seconds
Only appears if the gate operator
is set up as a Master or a Slave.
Available settings are 1 through
20. Each increment adds ½ second
time delay following a command to
open before the operator activates.
Provides up to a 10 second time
delay.
DUAL GATE inputs
on both operators
17
RT 0 (60 SECS)
MAXIMUM RUN TIMER
0 = 60 Seconds
max run,
1 = 300 Seconds
max run
Doesn't appear in SlideSmart.
Assigns a motor run time of 60 or
300 seconds. If the gate opening
or closure takes longer than 60
seconds, you’ll need to set the run
timer to 1.
(N/A)
18
PO 0 (OFF)
PARTIAL OPEN
0 = OFF
7 = 7 ft, 8 = 8ft,
through 32 = 32
ft
Sets distance (from closed gate
position) where gate stops if the
partial open input is activated.
When a number is entered in
PO display, open partial input
becomes operational.
OPEN PARTIAL COM
19
EC 0 (STOP ONLY)
EYE CLOSE LOGIC
0 = Close eye
stops only
1 = 2s reverse to
open
2 = Full Open
Default setting is non-reversal if
close photo eye is triggered while
closing. A setting of 1 causes gate
to reverse toward open for two
seconds if triggered while closing.
A setting of 2 reverses the gate to
full open.
Sensor Common
Sensor Input
DISPLAY AND MENU OPTIONS
MX4505 Rev. E ©2020
64
hysecurity.com | 800-321-9947
SlideSmart DC Programming and Operations