Table 10. Smart DC Controller - Installer Menu Functions
Ref.
No.
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
DC Controller
Display
Connections
36
LT 3 (75 SECS)
LOITERING ALERT
0 = 0 seconds
1 = 15 seconds
2 = 45 seconds
3 = 75 seconds
4 = 105 seconds
5 = 135 seconds
This function monitors activation
of the Outside Obstruction Loop
when there is no activation of
the gate. When the adjustable
period of time is exceeded, User
Relay No. 13 triggers and reports
loitering in the diagnostics log.
Adjust the time delay before
activating the user relay. Maximum
time setting is 135 seconds. See
Setting the User Relay Function in
the Installer Menu
NOTE:
This menu controls a user
relay set to Function No. 13
User relays
37
SA 0 (OFF)
STC ADDRESS
0 = No network
1 to 99 Network
"drop" address
Set system address for network
communication:
0 = no network communication
1 - 99 sets individual polling
addresses.
RS-485
38
ELD 0 (RUN MODE)
EXIT LOOP SET
0 = Run mode
1 = Show
frequency
2 = Show call
level 0-7
3 = Set
Frequency
Controls Hy5A or Hy5B Free
Exit detector. If an Hy5B is used,
additional settings of 4-8 are
available.
Hy5B
DISPLAY AND MENU OPTIONS
MX4505 Rev. E ©2020
SlideSmart DC Programming and Operations
hysecurity.com | 800-321-9947