DISPLAY AND MENU OPTIONS
VIEWING OPERATOR STATUS DISPLAYS
Press the MENU button once and the operator status displays appear in two second intervals. Pertinent
information appears to provide a quick overview of the operator’s status or con
fi
gurations. Refer to Table 7.
Table 7. Viewing Operator Status Displays
Display
Variables
Description
SOFTWARE VERSION
H5.##
Software version and revision
number are hard-coded in Smart DC
Controller.
Displays software version when you
press RESET or cycle power. You will
need software version when calling
Technical Support.
DUAL GATE
<PRIMARY>
PRIMARY or SECONDARY (Display
only appears when operator is used in
duel gate systems.)
Indicates, in a dual gate setting,
whether operator is set to Primary
or Secondary. Setting is assigned in
Installer Menu.
OT <15>D
SLIDESMART DC20
OT 15 = SlideSmart DC 15 at 1 ft/s
OT 16 = SlideSmart DC 10F at 2 ft/s
Indicates what type of operator the
board is programmed as.
<LEFT> HAND
LEFT or RIGHT
Designates which way a gate opens
viewed from operator. If it slides
left, it is a left-hand gate. Gate
handing is established in the initial
Setup Menu.
UC <2>
USAGE CLASS
1, 2, 3, or 4
Displays operator’s Usage Class
designation per UL 325 standards.
Refer to "Safety Requirements" on
page 16.
BT 0 (STANDARD)
BATTERY TYPE
0 = 8Ah (standard factory issue)
1 = 50Ah (optional upgrade)
2 = 110Ah (option)
Con
fi
rms operator’s battery type.
If you use larger capacity batteries
you must con
fi
gure operator
through Installer Menu.
See BT - BATTERY TYPE.
D <32>.0 VDC
BATTERY VOLTAGE
Number varies depending on voltage
that charger is providing.
Displays actual charging voltage.
CC<002600>
CYCLE COUNT
One cycle equals a full open and
close sequence.
Displays number of cycles gate
operator has incurred. Similar to
an odometer, it resets to zero after
999,999 cycles.
CT 0 (OFF)
CLOSE TIMER
The
fi
rst menu item in the User Menu.
See "User Menu" on page 47.
NOTE:
You can also access Installer
Menu from this display. See
"INSTALLER MENU" on page 54.
Displays number of seconds before
open gate initiates closure.
MX4505 Rev. E ©2020
46
hysecurity.com | 800-321-9947
SlideSmart DC Programming and Operations