![Nice HySecurity SlideSmart DC Series Installation And Programming Manual Download Page 48](http://html1.mh-extra.com/html/nice-hysecurity/slidesmart-dc-series/slidesmart-dc-series_installation-and-programming-manual_1687273048.webp)
DISPLAY AND MENU OPTIONS
SETTING THE TIME AND DATE
A feature of the Smart DC Controller is its 24-hour,
365 day clock. Make sure it is set to the appropriate
time zone. An accurate time and date allows the
diagnostic log to date stamp operational data
which indicates when Alerts, Faults and Errors
occur. The log helps in troubleshooting and can
be viewed via a laptop connected to the USB or
RS232 port. For more information, refer to "Smart
DC Controller Troubleshooting" on page 98.
To set or adjust the time or date, take the following
steps:
1.
At a gate status display, press the MENU
button twice. This accesses the User Menu and
the CLOSE TIMER display appears.
2.
Press NEXT or PREV until the SET CLOCK
display appears.
3.
Press SELECT. CL blinks.
4.
Press NEXT or PREV to change the number
to 1.
5.
Press SELECT to accept the display.
6.
The date and time display appears. Use the
SELECT and NEXT buttons in the same manner
as before to adjust the date and time.
7.
To accept what appears on the date and time
display, press SELECT.
8.
To exit the User Menu, press the MENU button.
NOTICE
A date or time
fi
eld must be blinking before it
can be changed.
A gate status appears in the display indicating
you have returned to Run Mode.
Figure 42. Setting Time and Date
SETTING AC POWER LOSS GATE FUNCTION
Setting in AC LOSS display determines what
action operator performs during an AC power loss.
Settings help reduce battery drain. You can choose
between four settings depending on customer
preferences. DC Solar Powered units can only be
set for AP0 or AP1.
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate
status display.
2. To access the
User Menu,
press the MENU
button twice.
3. Press NEXT until
the SET CLOCK
display appears.
Use the
navigational
buttons to select
1.
4. Change the time
and date using
the NEXT and
SELECT buttons.
CL 1
SET CLOCK
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
08/01/18
00:00
^^
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
NOTICE
A lithium coin battery, on the Smart DC
Controller board, supports the clock so the
date and time is retained even when the main
power is turned off. Replace the battery every
fi
ve years with a DL 2025, DL 2032 or CR 2025
or CR 2032 battery. Refer to "Clock Battery
Replacement" on page 117.
MX4505 Rev. E ©2020
48
hysecurity.com | 800-321-9947
SlideSmart DC Programming and Operations