SAFETY REQUIREMENTS
The following sensors have been tested with HySecurity gate operators by an independent laboratory and certi
fi
ed to
comply with UL 325 7th Edition. Select sensors from this list for UL compliant gate automation solutions. Contact the
sensor manufacturer for speci
fi
c recommendations for use.
CAUTION
All external entrapment protection sensors must have NC sensor outputs and be wired to the SENSOR COM
terminal for monitoring and powering purposes. Depending on software version, the sensor becomes powered
when the gate operator’s motor runs or is always powered when the operator is connected to AC power.
Installers must assess each specifi c site and
install sensors that protect all potential entrapment zones.
For more information visit Gate Safety at www.hysecurity.com/gatesafety or
see latest operator manual at www.hysecurity.com/contact-us/technical-support/installation-manuals
Protects open direction
(EDGE OPEN)
1
A
Install Edge for
Draw-in Zone
Trailing End
Leading End
PUBLIC
SECURE
2
Install Photo eye
Protects Leading End
(EYE CLOSE)
Slide Gate
Common
Entrapment
Zones
Indicates Additional Potential Entrapment Zone
A
MX4505 Rev. E ©2020
SlideSmart DC Programming and Operations
hysecurity.com | 800-321-9947
13