NOTE
The distance (a) between the adjacent rows depends
on the angle (
˞
) and the solar radiation angle (
˟
).
The distance between the rows must be between 5
m and 11 m depending on local conditions. (The
distance can reduced if a greater shadow angle is
acceptable.)
8 Installation
2. Assemble the stand
Secure the bottom rails in the base according to the stand’s
hole pattern. Then secure the stand with M10 x 65-screws,
nuts and washers in the rear edge of the bottom rail. Then
secure using lock clamps according to the illustration.
Install the centre lock clamp on the stand with
M10 x 65-screws, washers and M10-nuts. Then secure the
lower centre locking clamp in the lower rail with M10 x 25and
washer. Screw in 4 M10 x 12 with locking washer from under-
neath.
NOTE
Lightly tighten the outer locking clamps screws so
that the clamps are not deformed. Do not press the
locking clamps together. Only screw the
M10 x 12-screws in the middle in lightly, and leave
room for the solar panel.
53
Chapter 4 |
Mounting
SOLAR FP215 P/PL