6. Secure the solar panel
When the solar panel has been pressed under the fixing
wedges, the screws must be tightened.
NOTE
Stop lug, fixing wedge and solar panel must be
seated together without any gaps!
Install the centre fixing wedge with M10 x 25 Allen screw,
washer and wing nut.
Do not tighten!
7. Installing the quick coupling/compensator
Carefully twist the quick coupling / compensator into the solar
panel.
NOTE
The O-rings in the quick coupling are treated with
special high temperature grease. No further lubrica-
tion is needed. Further lubrication can reduce the
service life and invalidate the warranty!
8. Install and secure the remaining solar panels
Install the second solar panel with the lower centre fixing
wedges on the mounting rails, remove the corner protection
and slide it together with the first solar panel. The submerged
tube for the temperature sensor must always be pointed up-
wards. The distance between the solar panels must be 24 mm
both laterally and vertically. Tighten the centre fixing wedges
with an Allen key.
NOTE
When you slide the solar panels together make sure
that the compensators are kept straight and are not
knocked or stubbed.
SOLAR FP215 P/PL
Chapter 4 |
Mounting