7.3 Performance tests
WF1966
7-7
Amplitude vs. frequency characteristics
Connection:
Use coaxial cable to connect FUNCTION OUT to AC voltmeter 2 (50
Ω
termination).
Setting:
Initialize, then set the amplitude to 20 Vp-p/open and select the frequency and
waveform as indicated in the table.
Measurement:
Measure the true rms output voltage for each frequency and waveform. (CH1,CH2)
Judgment:
The normal ranges are indicated in the table.
Waveform
1 kHz
Setting
100 kHz
Setting
to 1 MHz
to 5 MHz
to 10 MHz
to 20 MHz
to 50 MHz
――――
(Reference
value)
±
0.2 dB
+0.2/-0.5 dB +0.2/-1.0 dB
+0.3/-1.5 dB +1.0/-3.0 dB
(Reference
value)
――――
±
0.3 dB
――――
――――
――――
――――
(Reference
value)
――――
±
0.3 dB
――――
――――
――――
――――
(Reference
value)
――――
±
0.5 dB
――――
――――
――――
――――
(Reference
value)
――――
±
0.5 dB
――――
――――
――――
――――
Sinewave distortion
Connection:
Use coaxial cable to connect FUNCTION OUT to a distortion meter (50
Ω
termination).
Setting:
Initialize, then set the amplitude to 20 Vp-p/open and the frequency as indicated in the
table.
Measurement:
Measure the distortion (CH1,CH2)
Judgment:
The normal range is indicated in the table.
Frequency Normal
range
10 Hz to 100 kHz
0.3 % or less
(Bandwidth 500 kHz)
Summary of Contents for wf1966
Page 1: ...INSTRUCTION MANUAL NF Corporation WF1966 MULTIFUNCTION SYNTHESIZER...
Page 2: ......
Page 3: ...DA00008200 002 WF1966 2CH 50MHz SYNTHESIZER Instruction Manual...
Page 4: ......
Page 8: ......
Page 20: ......
Page 31: ...3 1 Panel description WF1966 3 3 Front panel...
Page 32: ...3 1 Panel description 3 4 WF1966 Rear panel...
Page 62: ......
Page 158: ......
Page 174: ......
Page 190: ......
Page 192: ......
Page 194: ......
Page 196: ......
Page 197: ......