5.5 Other settings
5-22
WF1966
LOAD function (equalize setting and output values) (
SYSTEM
: LOAD)
Operation is described for equalizing the amplitude (AMPTD) and DC offset (OFFSET) setting
values with the actual output values (FUNCTION OUT connector voltage).
The example is setting at the 100
Ω
load impedance.
Operation:
①
Press the
SYSTEM
key, then use the
and
keys to produce the following display (LOAD
flashes).
O P E N
S Y S T E M
:
3
L O A D
C O P Y 1
→
2
C O P Y 2
→
1
4
②
Press the
ENTER
key, then turn the
MODIFY
dial to produce the following display(SET flashes).
S E T
5 0
Ω
S Y S T E M
:
3
L O A D
C O P Y 1
→
2
C O P Y 2
→
1
4
③
Press the
key, then turn the
MODIFY
dial to set the load impedance to 100
Ω
.
The above setting calculates the actual voltage of FUNCTION OUT connector from the WF1966
output impedance (50
Ω
) and the load impedance for automatically changing the indicated value.
Other:
• The load impedance setting range is 45 to 999
Ω
, resolution is 1
Ω
.
• The WF1966 output impedance and voltage errors are not converted.
Summary of Contents for wf1966
Page 1: ...INSTRUCTION MANUAL NF Corporation WF1966 MULTIFUNCTION SYNTHESIZER...
Page 2: ......
Page 3: ...DA00008200 002 WF1966 2CH 50MHz SYNTHESIZER Instruction Manual...
Page 4: ......
Page 8: ......
Page 20: ......
Page 31: ...3 1 Panel description WF1966 3 3 Front panel...
Page 32: ...3 1 Panel description 3 4 WF1966 Rear panel...
Page 62: ......
Page 158: ......
Page 174: ......
Page 190: ......
Page 192: ......
Page 194: ......
Page 196: ......
Page 197: ......