with water to clear any debris.
Check the Sparger Nozzle outlet and ensure it is not clogged. Flush with
water to clear any debris.
If flushing with water does not clear the debris, the Air Intake and Sparger
Nozzle pieces can be removed from the main sparger body for better
cleaning access.
Before attaching the cleaned Air Sparger, prime the reclaim system and
allow it to run for 1-2 minutes to flush out the Recirculation Line between
the Reclaim unit and the tank.
Again, place the Control Switch in the “Hand” position. Re-install the
sparger onto the wall bracket and replace the recirculation line plumbing.
Be sure the top Air Intake port is not obstructed.
Re-prime and restart the reclaim system. Check that the sparger is flowing
water and drawing air.
Air Intake
Sparger Body
Sparger Nozzle