Controls and Electrical:
AB
VFD
I
1
I
2
I
4
I
3
I
5
I
6
L1
N
SIEMENS
ESC
OK
LOGO!
OUTPUT 4 X
RELAY/10A
Q1
Q2
Q3
Q4
Q1
Q2
Q4
I
1
I
2
I
4
I
3
L
1
N
Q3
RUN/STOP
Q1
Q2
Q4
I
1
I
2
I
4
I
3
L
1
N
Q3
RUN/STOP
1 2 3 4
ON
OFF
5 6 7 8 9 10
G
Ground
110 V Power (Common)
110 V Power (Hot)
3-Phase Power (230 V Red / Blue / Black) or
(460 V Orange / Yellow / Brown)
Safety
Warning! Hazardous voltage. Can shock, burn, or cause
death.
Disconnect power at the main panel before
connecting the electrical power supply to the
reclaim unit panel or working on electrical
connections.
Ground the reclaim unit before connecting to
the electrical power supply. Failure to ground
the reclaim unit can cause a severe or fatal
electrical shock hazard.
Step 1: Install, ground, wire and maintain the
reclaim unit in accordance with local electrical
codes and ordinances that apply. Consult with
local building inspector for local code
information.
Step 2: Ground the reclaim unit permanently using
a wire of size and type specified by local or
National Electrical Code.
Do not ground to a gas supply line!
Step 3: Connect ground wire first. Connect to
ground first, then to green grounding terminal
provided. Do not connect the reclaim unit power
supply until the unit is permanently grounded;
otherwise serious or fatal electrical shock hazard
may be caused.
Do not connect the 3-Phase reclaim power leads
to a 1-Phase power supply. Do not connect the
1-Phase reclaim power leads to a 3-Phase
power supply.
The supply voltage must be within ±10% of the
designated reclaim unit voltage as shown on
“Installation & Operating Instructions” label
on the electrical panel cover. Incorrect voltage
can cause fire or seriously damage reclaim unit
and voids warranty. If in doubt consult a
licensed electrician.
Caution! This Reclaim Unit has been evaluated for use
with water only.
For Assistance, Contact Pur-Water / Sacramento, CA
800-882-8854
Level
Switch
Terminals
Activation Signal
Relays (#2-4 Only)
Programmable Logic
Controller (PLC)
VFD
Power
Disconnect
Breakers
Activation
Terminals
110 V - 20 Amps
230 V - 30 Amps
460 V - 20 Amps
PurWater
Reclaim Control
Panel
Reclaim Control Box
Pressure
Switch
Pump Prime Button
Power
Disconnect
Switch
Control
Switch
(Hand / Off /
Auto)
Running /
Warning
Lights
Power /
Activation
Voltage
Label