1) Treated Water Line:
This line has a pressure gauge (and a pressure
transducer on some units) and is to be connected to the wash. Solenoid
valves (supplied by others) need to be installed and controlled by the
wash controller when water is demanded by the wash. Do not reduce the
line size until reaching the wash equipment to prevent flow restriction
and pressure reduction. If connecting to a high pressure pump, we
recommend piping directly into the pump and not into the pump suction
tank. (See Drawing #1S.)
2) City Water Line:
This line has a check valve that leads to two brass
solenoid valves on the reclaim unit. City water is to be connected, which will
then provide fresh water for a by-pass function to the wash and an
automatic pump prime operation. The city water supply line needs to be 1”
for the PW 100 series and 2” for the larger units to ensure enough pressure
and flow are available. Do not exceed a pressure of 100 psig on the city
water inlet.
Ozone Generator
Oxygen
Concentrator
Cyclones
Pump / Motor
and Basket
Strainer
Control
Box
Treated Water
Line
City Water Line
Recirculation Line
Pump Suction Line
Underflow Line